Failing bioprosthesis in systemic tricuspid position after a Senning procedure—Successful percutaneous tricuspid valve implantation

Andreas Eicken, Markus Kasel, Peter Ewert

Research output: Contribution to journalArticlepeer-review

2 Scopus citations

Abstract

We report on successful transvenous and transbaffle implantation of a 26-mm Sapien 3 valve into a failing tricuspid (“systemic”) biological prosthesis in a patient after a Senning–Brom operation for transposition of the great arteries.

Original languageEnglish
Pages (from-to)E137-E140
JournalCatheterization and Cardiovascular Interventions
Volume89
Issue number4
DOIs
StatePublished - 1 Mar 2017

Keywords

  • bioprosthetic tricuspid valve
  • transcatheter valve replacement
  • transposition of the great arteries
  • valve-in-valve replacement

Fingerprint

Dive into the research topics of 'Failing bioprosthesis in systemic tricuspid position after a Senning procedure—Successful percutaneous tricuspid valve implantation'. Together they form a unique fingerprint.

Cite this