Skip to main navigation Skip to search Skip to main content

Factors affecting the monitoring of the early setting of concrete by ultrasonic P-Waves

  • Ghent University

Research output: Chapter in Book/Report/Conference proceedingChapterpeer-review

1 Scopus citations

Abstract

Ultrasonic P-wave measurements are widely used to monitor concrete setting. Although the largest wave velocity increase occurs during setting, the earliest increase is rather caused by other factors. Air bubble migration, internal settling, formation of ettringite and early C-S-H, workability loss and thixotropy might affect the velocity change in time. Tests on mortar in which cement was replaced by ben-tonite, con firmed the possible influence of thixotropy on the measurements. The effect of air bubble migration, internal settling and workability loss was proven to be restricted by testing a mixture in which the cement was replaced by inert material. In a cement mixture, the precipitation of hydration products might however accelerate settling and workability loss. During cement hydration simulations, the change in porosity due to the formation of early C-S-H and ettringite was considered for the calculation of the elastic properties of the granular framework. Nevertheless, the calculated velocity hardly increased before percolation and thus could not confirm that the first velocity increase is attributed to formation of early hydration products. Thus, apart from thixotropy, none of the other factors could unarguably be indicated as the cause of early velocity increase.

Original languageEnglish
Title of host publicationNondestructive Testing of Materials and Structures :Proceedings of NDTMS-2011, Istanbul, Turkey,May 15-18, 2011
EditorsOral Buyukozturk
Pages423-424
Number of pages2
DOIs
StatePublished - 2012

Publication series

NameRILEM Bookseries
Volume6
ISSN (Print)2211-0844
ISSN (Electronic)2211-0852

Keywords

  • Concrete
  • Early setting
  • Monitoring
  • P-waves
  • Ultrasound

Fingerprint

Dive into the research topics of 'Factors affecting the monitoring of the early setting of concrete by ultrasonic P-Waves'. Together they form a unique fingerprint.

Cite this