TY - GEN
T1 - Extracting a purely non-rigid deformation field of a single structure
AU - Demirci, Stefanie
AU - Manstad-Hulaas, Frode
AU - Navab, Nassir
PY - 2009
Y1 - 2009
N2 - During endovascular aortic repair (EVAR) treatment, the aortic shape is subject to severe deformation that is imposed by medical instruments such as guide wires, catheters, and the stent graft. The problem definition of deformable registration of images covering the entire abdominal region, however, is highly ill-posed. We present a new method for extracting the deformation of an aneurysmatic aorta. The outline of the procedure includes initial rigid alignment of two abdominal scans, segmentation of abdominal vessel trees, and automatic reduction of their centerline structures to one specified region of interest around the aorta. Our non-rigid registration procedure then only computes local non-rigid deformation and leaves out all remaining global rigid transformations. In order to evaluate our method, experiments for the extraction of aortic deformation fields are conducted on 15 patient datasets from endovascular aortic repair (EVAR) treatment. A visual assessment of the registration results were performed by two vascular surgeons and one interventional radiologist who are all experts in EVAR procedures.
AB - During endovascular aortic repair (EVAR) treatment, the aortic shape is subject to severe deformation that is imposed by medical instruments such as guide wires, catheters, and the stent graft. The problem definition of deformable registration of images covering the entire abdominal region, however, is highly ill-posed. We present a new method for extracting the deformation of an aneurysmatic aorta. The outline of the procedure includes initial rigid alignment of two abdominal scans, segmentation of abdominal vessel trees, and automatic reduction of their centerline structures to one specified region of interest around the aorta. Our non-rigid registration procedure then only computes local non-rigid deformation and leaves out all remaining global rigid transformations. In order to evaluate our method, experiments for the extraction of aortic deformation fields are conducted on 15 patient datasets from endovascular aortic repair (EVAR) treatment. A visual assessment of the registration results were performed by two vascular surgeons and one interventional radiologist who are all experts in EVAR procedures.
UR - https://www.scopus.com/pages/publications/84879943526
U2 - 10.1007/978-3-540-93860-6_16
DO - 10.1007/978-3-540-93860-6_16
M3 - Conference contribution
AN - SCOPUS:84879943526
SN - 9783540938590
T3 - Informatik aktuell
SP - 76
EP - 81
BT - Bildverarbeitung fur die Medizin 2009
PB - Kluwer Academic Publishers
T2 - Workshops Bildverarbeitung fur die Medizin: Algorithmen - Systeme - Anwendungen, BVM 2009 - Workshop on Image Processing for Medicine: Algorithms - Systems - Applications, BVM 2009
Y2 - 22 March 2009 through 25 March 2009
ER -