TY - JOUR
T1 - Experimental and analytical evaluation of the in-plane behaviour of as-built and strengthened traditional wooden floors
AU - Mirra, Michele
AU - Ravenshorst, Geert
AU - van de Kuilen, Jan Willem
N1 - Publisher Copyright:
© 2020 The Authors
PY - 2020/5/15
Y1 - 2020/5/15
N2 - Traditional timber floors cannot normally withstand horizontal seismic loads without large deformations. This may lead to a corresponding out-of-plane collapse of masonry walls in existing buildings. This situation is even more critical in the Netherlands, around the city of Groningen, where human-induced earthquakes started to take place. Since no seismic events have been experienced until recently, none of the existing buildings was designed with seismic events in mind, with no exception for the timber floors: therefore, it was necessary to characterize their in-plane response. To obtain representative results, firstly floor and roof samples were extracted from existing buildings. The relevant material properties were determined, together with the plank-joist connections behaviour. Replicas were then built with new material and tested to confirm the similarity in response compared to extracted samples. Based on these results, full-scale replicated diaphragms were constructed, and tested quasi-static reversed-cyclic in their plane, either parallel or perpendicular to the joists. Besides characterizing as-built diaphragms, a simple strengthening technique with plywood panels was applied as well, improving their in-plane response in terms of strength, stiffness and energy dissipation, as test results confirm. This study is concluded with an analytical characterization of the diaphragms’ in-plane response, for as-built and strengthened configurations.
AB - Traditional timber floors cannot normally withstand horizontal seismic loads without large deformations. This may lead to a corresponding out-of-plane collapse of masonry walls in existing buildings. This situation is even more critical in the Netherlands, around the city of Groningen, where human-induced earthquakes started to take place. Since no seismic events have been experienced until recently, none of the existing buildings was designed with seismic events in mind, with no exception for the timber floors: therefore, it was necessary to characterize their in-plane response. To obtain representative results, firstly floor and roof samples were extracted from existing buildings. The relevant material properties were determined, together with the plank-joist connections behaviour. Replicas were then built with new material and tested to confirm the similarity in response compared to extracted samples. Based on these results, full-scale replicated diaphragms were constructed, and tested quasi-static reversed-cyclic in their plane, either parallel or perpendicular to the joists. Besides characterizing as-built diaphragms, a simple strengthening technique with plywood panels was applied as well, improving their in-plane response in terms of strength, stiffness and energy dissipation, as test results confirm. This study is concluded with an analytical characterization of the diaphragms’ in-plane response, for as-built and strengthened configurations.
KW - Floor stiffness
KW - Retrofitting
KW - Seismic rehabilitation
KW - Strengthening techniques
KW - Timber floors
UR - http://www.scopus.com/inward/record.url?scp=85082004128&partnerID=8YFLogxK
U2 - 10.1016/j.engstruct.2020.110432
DO - 10.1016/j.engstruct.2020.110432
M3 - Article
AN - SCOPUS:85082004128
SN - 0141-0296
VL - 211
JO - Engineering Structures
JF - Engineering Structures
M1 - 110432
ER -