TY - JOUR
T1 - Estimating serum-ionized magnesium concentration in hemodialysis patients
AU - Holzmann-Littig, Christopher
AU - Kuechle, Claudius
AU - Bietenbeck, Andreas
AU - McCallum, Wendy
AU - Heemann, Uwe
AU - Renders, Lutz
AU - Steubl, Dominik
N1 - Publisher Copyright:
© 2021 The Authors. Hemodialysis International published by Wiley Periodicals LLC on behalf of International Society for Hemodialysis.
PY - 2021/10
Y1 - 2021/10
N2 - Introduction: Cardiovascular mortality is significantly increased in kidney failure with replacement therapy (KFRT) patients, which is partly mediated by enhanced vascular calcification. Magnesium appears to have anticalcifying capabilities, and hypomagnesemia has been associated with increased mortality in KFRT patients. Ionized magnesium represents the biologically and physiologically active form. As serum ionized magnesium (Mgion) is difficult to assess in clinical routine estimating equations derived from routinely assessed laboratory parameters could facilitate medical treatment. Methods: We developed equations to estimate serum Mgion using linear regression analysis in 191 hemodialysis (HD) patients. Reference test was measured ionized magnesium (Mgion). As index tests, we chose estimated Mgion using total magnesium (Mgtot) and other laboratory and demographic variable candidates. Equations were internally validated, using 749 subsequent Mgion measurements. Findings: The median patient age was 65 years, 67.5% of the patients were male. Median (interquartile range [IQR]) measured Mgion was 0.64 [0.57, 0.72] mmol/L, 11 (6%) patients were hypo- (i.e., <0.45 mmol/L) and 127 (66%) were hypermagnesemic (>0.60 mmol/L). The final equation at the end of the development process included Mgtot, serum ionized, and total calcium concentrations. In the validation dataset, bias (i.e., median difference between measured and estimated Mgion, −0.017 [−0.020, −0.014] mmol/L) and precision (i.e., IQR of bias 0.043 [0.039, 0.047] mmol/L) were small, 90% [88, 93] of estimated values were ±10% of measured values. The equation detected normomagnesemia with overall good diagnostic accuracy (area under the receiver-operating curve 0.91 [0.89, 0.93]). Discussion: Mgion can be estimated from equations containing routinely assessed laboratory variables with high accuracy and good overall performance. These equations might simplify the assessment of ionized magnesium levels in the individual hemodialysis patients and help the treating physician to guide the overall treatment.
AB - Introduction: Cardiovascular mortality is significantly increased in kidney failure with replacement therapy (KFRT) patients, which is partly mediated by enhanced vascular calcification. Magnesium appears to have anticalcifying capabilities, and hypomagnesemia has been associated with increased mortality in KFRT patients. Ionized magnesium represents the biologically and physiologically active form. As serum ionized magnesium (Mgion) is difficult to assess in clinical routine estimating equations derived from routinely assessed laboratory parameters could facilitate medical treatment. Methods: We developed equations to estimate serum Mgion using linear regression analysis in 191 hemodialysis (HD) patients. Reference test was measured ionized magnesium (Mgion). As index tests, we chose estimated Mgion using total magnesium (Mgtot) and other laboratory and demographic variable candidates. Equations were internally validated, using 749 subsequent Mgion measurements. Findings: The median patient age was 65 years, 67.5% of the patients were male. Median (interquartile range [IQR]) measured Mgion was 0.64 [0.57, 0.72] mmol/L, 11 (6%) patients were hypo- (i.e., <0.45 mmol/L) and 127 (66%) were hypermagnesemic (>0.60 mmol/L). The final equation at the end of the development process included Mgtot, serum ionized, and total calcium concentrations. In the validation dataset, bias (i.e., median difference between measured and estimated Mgion, −0.017 [−0.020, −0.014] mmol/L) and precision (i.e., IQR of bias 0.043 [0.039, 0.047] mmol/L) were small, 90% [88, 93] of estimated values were ±10% of measured values. The equation detected normomagnesemia with overall good diagnostic accuracy (area under the receiver-operating curve 0.91 [0.89, 0.93]). Discussion: Mgion can be estimated from equations containing routinely assessed laboratory variables with high accuracy and good overall performance. These equations might simplify the assessment of ionized magnesium levels in the individual hemodialysis patients and help the treating physician to guide the overall treatment.
KW - calcification
KW - equation
KW - hemodialysis
KW - magnesium
KW - mortality
UR - http://www.scopus.com/inward/record.url?scp=85107977390&partnerID=8YFLogxK
U2 - 10.1111/hdi.12944
DO - 10.1111/hdi.12944
M3 - Review article
C2 - 34132041
AN - SCOPUS:85107977390
SN - 1492-7535
VL - 25
SP - 523
EP - 531
JO - Hemodialysis International
JF - Hemodialysis International
IS - 4
ER -