ESR and LESR studies in CVD diamond

C. F.O. Graeff, E. Rohrer, C. E. Nebel, M. Stutzmann, H. Guettler, R. Zachai

Research output: Contribution to journalConference articlepeer-review

4 Scopus citations

Abstract

CVD diamond films with nitrogen content varying from 10 ppm to 132 ppm have been studied by electron spin resonance (ESR), light-induced ESR (LESR) as well as spin-dependent conductivity (SDC). Two characteristic signals have been observed. A carbon-related defect line with g = 2.0029±0.0002 and width 4±1 G, is observed in ESR, LESR and SDC. The intensity of this line measured by ESR increases linearly with nitrogen content. For low-defect-density samples, or after illuminating the high-defect-density samples with UV light, a second signal is observed both in ESR and LESR, but not in SDC, with a central line at g = 2.0024±0.001 and width 0.2±0.1 G and related hyperfine satellites ≈30 G away from the central line. This line is assigned to isolated substitutional nitrogen, the so-called P1 center. The density of N-related paramagnetic states is strongly affected by illumination and heat treatments. Spin-dependent conductivity measurements show that the dark conductivity at room temperature in CVD-diamond is dominated by hopping at the g = 2.0029 defects.

Original languageEnglish
Pages (from-to)495-500
Number of pages6
JournalMaterials Research Society Symposium - Proceedings
Volume423
DOIs
StatePublished - 1996
EventProceedings of the 1996 MRS Spring Symposium - San Francisco, CA, USA
Duration: 8 Apr 199612 Apr 1996

Fingerprint

Dive into the research topics of 'ESR and LESR studies in CVD diamond'. Together they form a unique fingerprint.

Cite this