Abstract
For medical purposes, materials are required that store and target specifically deliver exogenous nitric oxide (NO). Partially zinc-exchanged Na-LTA (Linde type A) zeolite (Zn-LTA) has high potential in this respect due to its non-toxicity and adsorption capacity for NO. In contrast to NO adsorbed to LTA zeolites prepared for catalytic purposes, lower dehydration temperature prior to NO adsorption is used to achieve a balance between production cost and high activity. In order to study the interaction of NO with the metal sites in the samples prepared under these medical conditions, continuous-wave X-band electron paramagnetic resonance has been applied. In contrast to Na-LTA with only one weakly interacting NO monomer, three different monomers, having stronger interaction to the metal sites than in Na-LTA, were observed in Zn-LTA. To improve the storage capacity of Zn-LTA, higher dehydration temperatures would be necessary.
Original language | English |
---|---|
Pages (from-to) | 619-627 |
Number of pages | 9 |
Journal | Applied Magnetic Resonance |
Volume | 37 |
Issue number | 1 |
DOIs | |
State | Published - 2010 |
Externally published | Yes |