Abstract
This paper investigates the utilization of a machine drive configuration that permits to eliminate the common-mode voltage. The drive system employs a four-phase inverter and a four-phase induction motor. A complete analytical model of the four-phase induction machine is presented. The pulse-width modulation technique for generating the gate signals for the power switches of the four-phase inverter is also presented. Simulation and experimental results are presented to demonstrate the feasibility of the proposed solution.
| Original language | English |
|---|---|
| Pages (from-to) | 859-866 |
| Number of pages | 8 |
| Journal | Conference Record - IAS Annual Meeting (IEEE Industry Applications Society) |
| Volume | 2 |
| DOIs | |
| State | Published - 2001 |
| Externally published | Yes |
Fingerprint
Dive into the research topics of 'Eliminating the common-mode voltage in AC drive systems using a four-phase machine'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver