TY - JOUR
T1 - Effect of Spraying Polyurea on the Anti-Blast Performance of the Ultra-High Performance Concrete Slab
AU - Gao, Bin
AU - Wu, Jun
AU - Chen, Qinyi
AU - Yu, Jun
AU - Yu, Haitao
N1 - Publisher Copyright:
© 2022 by the authors.
PY - 2022/12
Y1 - 2022/12
N2 - Recently, polyurea has been applied to improve the anti-blast performance of metal plates, masonry walls, and concrete structures. However, the strengthening effectiveness of polyurea on ultra-high performance concrete (UHPC) slabs with an overall response is still unclear. Hence, this paper examined the strengthening effectiveness of polyurea on the anti-blast performance of UHPC slabs under near-field explosion by the finite element (FE) method. First, a benchmark finite element model for UHPC and polyurea-UHPC (PUHPC) slabs under blast loading was established and validated by field blast tests, with scaled distances ranging from 0.4 m/kg1/3 to 0.8 m/kg1/3. After that, parametric analysis was conducted to fully understand the strengthening effectiveness of polyurea on the anti-blast performance of the UHPC slab. Factors including the scaled distance, polyurea thickness, span-to-depth ratio of the slab, and longitudinal reinforcement ratio were considered. The results showed that (1) spraying polyurea on the rear face of the UHPC slab can reduce the width of cracks and mitigate the damage of specimens; (2) the strengthening effectiveness of polyurea on the UHPC slab became prominent when the UHPC slab suffered a larger maximum deflection; (3) in terms of the deflection and energy absorption capacity of PUHPC slabs, the optimum thickness of sprayed polyurea was determined to be 8 mm to 12 mm; and (4) by adopting the multiple nonlinear regression method, a prediction formula was developed to quickly obtain the end rotation of the UHPC slab strengthened with polyurea under near-field explosions.
AB - Recently, polyurea has been applied to improve the anti-blast performance of metal plates, masonry walls, and concrete structures. However, the strengthening effectiveness of polyurea on ultra-high performance concrete (UHPC) slabs with an overall response is still unclear. Hence, this paper examined the strengthening effectiveness of polyurea on the anti-blast performance of UHPC slabs under near-field explosion by the finite element (FE) method. First, a benchmark finite element model for UHPC and polyurea-UHPC (PUHPC) slabs under blast loading was established and validated by field blast tests, with scaled distances ranging from 0.4 m/kg1/3 to 0.8 m/kg1/3. After that, parametric analysis was conducted to fully understand the strengthening effectiveness of polyurea on the anti-blast performance of the UHPC slab. Factors including the scaled distance, polyurea thickness, span-to-depth ratio of the slab, and longitudinal reinforcement ratio were considered. The results showed that (1) spraying polyurea on the rear face of the UHPC slab can reduce the width of cracks and mitigate the damage of specimens; (2) the strengthening effectiveness of polyurea on the UHPC slab became prominent when the UHPC slab suffered a larger maximum deflection; (3) in terms of the deflection and energy absorption capacity of PUHPC slabs, the optimum thickness of sprayed polyurea was determined to be 8 mm to 12 mm; and (4) by adopting the multiple nonlinear regression method, a prediction formula was developed to quickly obtain the end rotation of the UHPC slab strengthened with polyurea under near-field explosions.
KW - UHPC slabs
KW - near-field explosion
KW - parametric analysis
KW - polyurea
KW - strengthening effectiveness
UR - http://www.scopus.com/inward/record.url?scp=85144530843&partnerID=8YFLogxK
U2 - 10.3390/s22249888
DO - 10.3390/s22249888
M3 - Article
C2 - 36560255
AN - SCOPUS:85144530843
SN - 1424-8220
VL - 22
JO - Sensors (Switzerland)
JF - Sensors (Switzerland)
IS - 24
M1 - 9888
ER -