Effect of electrode position on outcome of low-energy intracardiac cardioversion of atrial fibrillation

Eckhard Alt, Claus Schmitt, Richard Ammer, Andreas Plewan, Fred Evans, Jay Pasquantonio, Trey Ideker, Günter Lehmann, Katja Pütter, Albert Schömig

Research output: Contribution to journalArticlepeer-review

40 Scopus citations

Abstract

The aim of this study was to evaluate the new method of low-energy, catheter-based intracardiac cardioversion in patients with chronic atrial fibrillation (AF) and to compare 2 different lead positions. Accordingly, we prospectively studied 80 consecutive patients with chronic AF (9.8 ± 7.9 months) who were randomly assigned to undergo internal cardioversion either via defibrillation electrodes placed in the right atrium and coronary sinus (coronary sinus group) or via defibrillation electrodes placed in the right atrium and left pulmonary artery (pulmonary artery group). Intracardiac shocks were delivered by an external defibrillator synchronized to the QRS complex. After conversion, all patients were treated orally with sotalol (mean daily dose, 189 ± 63 mg/day). For conversion to sinus rhythm, the overall mean energy requirement was 5.6 ± 3.1 J. In the coronary sinus group, cardioversion was achieved in 35 of 38 patients at a mean energy level of 4.1 ± 2.3 J (range 1.0 to 9.9), and in the pulmonary artery group in 39 of 42 patients with 7.2 ± 3.1 J (range 2.5 to 14.8). Although there was no difference with regard to success rate, the energy differed significantly between the 2 groups (p <0.01). Mean lead impedance was 56.4 ± 7.0 Ω and 54.6 ± 8.4 Ω, respectively (p = NS). No serious complications were observed in either lead group. At a mean follow up of 14.2 ± 7.0 months, 54% and 56%, respectively, of patients who had been converted successfully remained in sinus rhythm. Thus, low-energy biphasic shocks delivered between the right atrium and coronary sinus or pulmonary artery are equally effective for cardioversion of patients with chronic AF. The energy requirements for conversion from a pulmonary artery electrode position are higher than for the coronary sinus position.

Original languageEnglish
Pages (from-to)621-625
Number of pages5
JournalAmerican Journal of Cardiology
Volume79
Issue number5
DOIs
StatePublished - 1 Mar 1997

Fingerprint

Dive into the research topics of 'Effect of electrode position on outcome of low-energy intracardiac cardioversion of atrial fibrillation'. Together they form a unique fingerprint.

Cite this