Abstract
Purpose: To evaluate the consequences of a planning volume definition based on multiple CTs and the application of off-line setup error correction for the treatment of prostate cancer with intensity-modulated radiotherapy (IMRT). Further, to compare various setup correction protocols (SCP) by their influence on the average dose distributions. Materials and methods: A planning target volume (PTV) consisting of the bounding volume of prostate contours of five CTs (CTV_hull) plus an additional margin of 5 mm and a virtual Rectum_hull volume (the solid bounding volume of the five corresponding rectum contours) are used for treatment planning. Simulations of treatment courses with the non-parametric bootstrap method allow to estimate the distribution of the expected equivalent uniform dose (EUD). The impact of off-line setup error correction protocols is evaluated based on estimated EUD distributions. Results: Off-line SCP allow to achieve the intended prostate and rectum EUD and a reliable coverage of the CTV despite the reduced margins. The EUD of the virtual hull volumes is a good estimate for the EUD of prostate and rectal wall. Conclusion: Treatment planning based on Rectum_hull and CTV_hull plus setup margin as PTV in combination with SCP results in a robust and safe IMRT planning concept.
Original language | English |
---|---|
Pages (from-to) | 35.E1-35.E8 |
Journal | Radiotherapy and Oncology |
Volume | 76 |
Issue number | 1 |
DOIs | |
State | Published - Jul 2005 |
Externally published | Yes |
Keywords
- IMRT
- Organ motion
- Prostate cancer
- Setup error correction
- Treatment planning