TY - JOUR
T1 - Development of a sensitive enzyme immunoassay for LH determination in bovine plasma using the streptavidin-biotin technique
AU - Mutayoba, B. M.
AU - Meyer, H. H.D.
AU - Schams, D.
AU - Schallenberger, E.
PY - 1990
Y1 - 1990
N2 - Using the biotin-streptavidin amplification technique, highly sensitive specific second-antibody enzyme immunoassays for determining LH in bovine plasma with long (48 h) and short (4 H) incubation periods were developed. Biotin was linked to bLH by the N-hydroxysuccimidine method and the product (biotinyl-bLH) used to bridge between streptavidin-peroxidase and the immobilised bLH antibody in competitive tests. The assays were validated and their performance compaired with a radioimmunoassay currently in use. The sensitivities of the long and short incubation enzyme immunoassays (8 pg and 15 pg/well, respectively) were superior to that of 5-day incubation radioimmunoassay (100 pg/tube). Plasma interference in both assays were acceptable and volumes of 5 to 40 μl gave parallel standard curves and comparable LH levels, 10-20 μl plasma was sufficient to measure LH baseline levels by the long incubation enzyme immunoassay. The mean recovery of added standard bLH to plasma samples containing different endogenous LH was >90% (range 91.7-112) in both assays. The intra- and inter-assay variations of both assays were less than 10 and 17%, respectively. When both enzyme immunoassay and radioimmunoassay were used to measure LH in cyclic cows, the basal levels measured by enzyme immunoassay were lower that that measured by radioimmunoassay. Enzyme immunoassay offers an attractive alternative to the lengthy radioimmunoassay in current usage, with an added advantage of employing non-isotopic label.
AB - Using the biotin-streptavidin amplification technique, highly sensitive specific second-antibody enzyme immunoassays for determining LH in bovine plasma with long (48 h) and short (4 H) incubation periods were developed. Biotin was linked to bLH by the N-hydroxysuccimidine method and the product (biotinyl-bLH) used to bridge between streptavidin-peroxidase and the immobilised bLH antibody in competitive tests. The assays were validated and their performance compaired with a radioimmunoassay currently in use. The sensitivities of the long and short incubation enzyme immunoassays (8 pg and 15 pg/well, respectively) were superior to that of 5-day incubation radioimmunoassay (100 pg/tube). Plasma interference in both assays were acceptable and volumes of 5 to 40 μl gave parallel standard curves and comparable LH levels, 10-20 μl plasma was sufficient to measure LH baseline levels by the long incubation enzyme immunoassay. The mean recovery of added standard bLH to plasma samples containing different endogenous LH was >90% (range 91.7-112) in both assays. The intra- and inter-assay variations of both assays were less than 10 and 17%, respectively. When both enzyme immunoassay and radioimmunoassay were used to measure LH in cyclic cows, the basal levels measured by enzyme immunoassay were lower that that measured by radioimmunoassay. Enzyme immunoassay offers an attractive alternative to the lengthy radioimmunoassay in current usage, with an added advantage of employing non-isotopic label.
UR - http://www.scopus.com/inward/record.url?scp=0025181442&partnerID=8YFLogxK
U2 - 10.1530/acta.0.1220227
DO - 10.1530/acta.0.1220227
M3 - Article
C2 - 2180243
AN - SCOPUS:0025181442
SN - 0001-5598
VL - 122
SP - 227
EP - 232
JO - Acta Endocrinologica
JF - Acta Endocrinologica
IS - 2
ER -