Abstract

Background: Because of the anatomy of the mastoid and the size of the actuator, positioning of the Vibrant Bonebridge B-FMT can be difficult without prior evaluation of the individual computed tomography (CT) scan of the temporal bone. Development of a user-friendly CT data viewer to enable positioning of the B-FMT in the temporal bone model, whilst identifying individual, potential anatomic conflicts and offering possible solutions could provide a useful tool for preoperative positioning. Objectives: Aim of the study was to define the requirements of a Vibrant Bonebridge viewer and construct a prototype. Materials and methods: Based on a ZIBAmira software version and inclusion of a B-FMT model upon creation of a model of the temporal bone-which allows the intuitive estimation of individual, anatomic conflicts-a Vibrant Bonebridge viewer was constructed. Results: The segmentation time of the individual digital imaging and communications in medicine (DICOM) data set is about 5 min. Positioning within the individual three-dimensional temporal bone model allows quantitative and qualitative estimation of conflicts (sigmoid sinus, middle cranial fossa) and determination of a preferred position for the B-FMT. Lifting of the B-FMT can be simulated with the help of a virtual washer. Conclusion: The Vibrant Bonebridge viewer reliably allows simulation of B-FMT positioning. The clinical value of the viewer still has to be evaluated.

Translated title of the contributionDevelopment of a computed tomography data-based Vibrant Bonebridge viewer
Original languageEnglish
Pages (from-to)439-442
Number of pages4
JournalHNO
Volume62
Issue number6
DOIs
StatePublished - Jun 2014
Externally publishedYes

Keywords

  • 3D model
  • Computed tomography
  • Hearing aids
  • Segmentation
  • Vibrant Bonebridge