TY - JOUR
T1 - Detection Threshold and Reproducibility of 68Ga-PSMA11 PET/CT in a Mouse Model of Prostate Cancer
AU - Lückerath, Katharina
AU - Stuparu, Andreea D.
AU - Wei, Liu
AU - Kim, Woosuk
AU - Radu, Caius G.
AU - Mona, Christine E.
AU - Calais, Jeremie
AU - Rettig, Matthew
AU - Reiter, Robert E.
AU - Czernin, Johannes
AU - Slavik, Roger
AU - Herrmann, Ken
AU - Eiber, Matthias
AU - Fendler, Wolfgang P.
N1 - Publisher Copyright:
© 2018 by the Society of Nuclear Medicine and Molecular Imaging.
PY - 2018/9/1
Y1 - 2018/9/1
N2 - To improve prostate-specific membrane antigen (PSMA)-targeted theranostic approaches, robust murine models of prostate cancer are needed. However, important characteristics of preclinical PSMA imaging-that is, the reproducibility of the imaging signal and the relationship between quantitative cell surface PSMA expression and lesion detectability with small-animal PET/CT-have not been defined yet. Methods: Murine prostate cancer RM1 sublines (ras myc transformed cells of C=7BL/6 prostate origin) expressing varying levels of human PSMA were injected into the shoulder of C57BL/6 mice on day 0. 68Ga-PSMA11 PET/CT was performed on days 7 and 8 and interpreted by 2 masked readers to determine interday and interreader reproducibility. PSMA expression was quantified on days 7 and 8 by flow cytometry of fine-needle aspiration tumor biopsy samples. Cell surface PSMA expression was correlated with PET signal. The threshold for PET positivity was based on the clinical Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE) criteria. Results: The maximum and average percentages of injected 68Ga-PSMA11 activity per gram of tissue (%IA/g) correlated nearly perfectly as determined by 2 independent readers and on 2 separate days (intraclass correlation coefficient, 1.00/0.89 and 0.95/0.88, respectively). The number of PSMA molecules per cell increased from the RM1-yellow fluorescent protein subline (PSMA-; 2,000/ cell) to the RM1-low subline (PSMA+; 17,000/cell), the RM1-medium subline (PSMA++; 22,000/cell), and the RM1-PGLS subline (PSMApositive, green fluorescent protein-positive, and luciferase-positive; PSMA+++; 45,000/cell). Expression levels correlated with the visual positivity rate on 68Ga-PSMA11 PET and with the PSMA PET %IA/g. The PSMA threshold for PET positivity was approximately 20,000 per cell. Signal correlation was close at lower PSMA levels (RM1- low to RM1-medium; 10-23 %IA/g) but was lost at higher PSMA levels (RM1-medium to RM1-PGLS; 23-27 %IA/g). Conclusion: The in vivo relationship between 68Ga-PSMA11 PET/CT and PSMA expression level in a murine model of prostate cancer was robust for lower cell surface PSMA expression levels (≤22,000/cell). Thus, preclinical 68Ga-PSMA11 PET/CT can be used as an imaging biomarker to test PSMA-targeted interventions in murine models.
AB - To improve prostate-specific membrane antigen (PSMA)-targeted theranostic approaches, robust murine models of prostate cancer are needed. However, important characteristics of preclinical PSMA imaging-that is, the reproducibility of the imaging signal and the relationship between quantitative cell surface PSMA expression and lesion detectability with small-animal PET/CT-have not been defined yet. Methods: Murine prostate cancer RM1 sublines (ras myc transformed cells of C=7BL/6 prostate origin) expressing varying levels of human PSMA were injected into the shoulder of C57BL/6 mice on day 0. 68Ga-PSMA11 PET/CT was performed on days 7 and 8 and interpreted by 2 masked readers to determine interday and interreader reproducibility. PSMA expression was quantified on days 7 and 8 by flow cytometry of fine-needle aspiration tumor biopsy samples. Cell surface PSMA expression was correlated with PET signal. The threshold for PET positivity was based on the clinical Prostate Cancer Molecular Imaging Standardized Evaluation (PROMISE) criteria. Results: The maximum and average percentages of injected 68Ga-PSMA11 activity per gram of tissue (%IA/g) correlated nearly perfectly as determined by 2 independent readers and on 2 separate days (intraclass correlation coefficient, 1.00/0.89 and 0.95/0.88, respectively). The number of PSMA molecules per cell increased from the RM1-yellow fluorescent protein subline (PSMA-; 2,000/ cell) to the RM1-low subline (PSMA+; 17,000/cell), the RM1-medium subline (PSMA++; 22,000/cell), and the RM1-PGLS subline (PSMApositive, green fluorescent protein-positive, and luciferase-positive; PSMA+++; 45,000/cell). Expression levels correlated with the visual positivity rate on 68Ga-PSMA11 PET and with the PSMA PET %IA/g. The PSMA threshold for PET positivity was approximately 20,000 per cell. Signal correlation was close at lower PSMA levels (RM1- low to RM1-medium; 10-23 %IA/g) but was lost at higher PSMA levels (RM1-medium to RM1-PGLS; 23-27 %IA/g). Conclusion: The in vivo relationship between 68Ga-PSMA11 PET/CT and PSMA expression level in a murine model of prostate cancer was robust for lower cell surface PSMA expression levels (≤22,000/cell). Thus, preclinical 68Ga-PSMA11 PET/CT can be used as an imaging biomarker to test PSMA-targeted interventions in murine models.
KW - PET
KW - PSMA
KW - Prostate cancer
KW - Reproducibility
KW - Threshold
UR - http://www.scopus.com/inward/record.url?scp=85053198607&partnerID=8YFLogxK
U2 - 10.2967/jnumed.118.207704
DO - 10.2967/jnumed.118.207704
M3 - Article
C2 - 29602819
AN - SCOPUS:85053198607
SN - 0161-5505
VL - 59
SP - 1392
EP - 1397
JO - Journal of Nuclear Medicine
JF - Journal of Nuclear Medicine
IS - 9
ER -