Design of a compact high-energy setup for x-ray phase-contrast imaging

Markus Schüttler, Andre Yaroshenko, Martin Bech, Guillaume Potdevin, Andreas Malecki, Michael Chabior, Johannes Wolf, Arne Tapfer, Jan Meiser, Danays Kunka, Maximilian Amberger, Jürgen Mohr, Franz Pfeiffer

Research output: Chapter in Book/Report/Conference proceedingConference contributionpeer-review

Abstract

The main shortcoming of conventional biomedical x-ray imaging is the weak soft-Tissue contrast caused by the small differences in the absorption coefficients between different materials. This issue can be addressed by x-ray phasesensitive imaging approaches, e.g. x-ray Talbot-Lau grating interferometry. The advantage of the three-grating Talbot-Lau approach is that it allows to acquire x-ray phase-contrast and dark-field images with a conventional lab source. However, through the introduction of the grating interferometer some constraints are imposed on the setup geometry. In general, the grating pitch and the mean x-ray energy determine the setup dimensions. The minimal length of the setup increases linearly with energy and is proportional to p2, where p is the grating pitch. Thus, a high-energy (100 keV) compact grating-based setup for x-ray imaging can be realized only if gratings with aspect-ratio of approximately 300 and a pitch of 1-2 μm were available. However, production challenges limit the availability of such gratings. In this study we consider the use of non-binary phase-gratings as means of designing a more compact grating interferometer for phase-contrast imaging. We present simulation and experimental data for both monochromatic and polychromatic case. The results reveal that phase-gratings with triangular-shaped structures yield visibilities that can be used for imaging purposes at significantly shorter distances than binary gratings. This opens the possibility to design a high-energy compact setup for x-ray phase-contrast imaging. Furthermore, we discuss different techniques to achieve triangular-shaped phase-shifting structures.

Original languageEnglish
Title of host publicationMedical Imaging 2014
Subtitle of host publicationPhysics of Medical Imaging
PublisherSPIE
ISBN (Print)9780819498267
DOIs
StatePublished - 2014
EventMedical Imaging 2014: Physics of Medical Imaging - San Diego, CA, United States
Duration: 17 Feb 201420 Feb 2014

Publication series

NameProgress in Biomedical Optics and Imaging - Proceedings of SPIE
Volume9033
ISSN (Print)1605-7422

Conference

ConferenceMedical Imaging 2014: Physics of Medical Imaging
Country/TerritoryUnited States
CitySan Diego, CA
Period17/02/1420/02/14

Keywords

  • Biomedical Imaging
  • Grating interferometry
  • Talbot-Lau interferometry
  • X-ray Phase-Contrast Imaging
  • X-ray interferometry

Fingerprint

Dive into the research topics of 'Design of a compact high-energy setup for x-ray phase-contrast imaging'. Together they form a unique fingerprint.

Cite this