TY - JOUR
T1 - Computed tomography angiography and myocardial computed tomography perfusion in patients with coronary stents
T2 - Prospective intraindividual comparison with conventional coronary angiography
AU - Rief, Matthias
AU - Zimmermann, Elke
AU - Stenzel, Fabian
AU - Martus, Peter
AU - Stangl, Karl
AU - Greupner, Johannes
AU - Knebel, Fabian
AU - Kranz, Anisha
AU - Schlattmann, Peter
AU - Laule, Michael
AU - Dewey, Marc
PY - 2013/10/15
Y1 - 2013/10/15
N2 - Objectives This study sought to determine whether adding myocardial computed tomography perfusion (CTP) to computed tomography angiography (CTA) improves diagnostic performance for coronary stents. Background CTA of coronary stents has been limited by nondiagnostic studies caused by metallic stent material and coronary motion. Methods CTA and CTP were performed in 91 consecutive patients with stents before quantitative coronary angiography, the reference standard for obstructive stenosis (≥50%). If a coronary stent or vessel was nondiagnostic on CTA, adenosine stress CTP in the corresponding myocardial territory was read for combined CTA/CTP. Results Patients had an average of 2.5 ± 1.8 coronary stents (1 to 10), with a diameter of 3.0 ± 0.5 mm. Significantly more patients were nondiagnostic for stent assessment by CTA (22%; mainly due to metal artifacts [75%] or motion [25%]) versus CTP (1%; p < 0.001; severe angina precluded CTP in 1 case). The per-patient diagnostic accuracy of CTA/CTP for stents (87%, 95% confidence interval [CI]: 78% to 93%) was significantly higher than that of CTA alone (71%, 95% CI: 61% to 80%; p < 0.001), mainly because nondiagnostic examinations were significantly reduced (p < 0.001). In the analysis of any coronary artery disease, diagnostic accuracy and nondiagnostic rate were also significantly improved by the addition of CTP (p < 0.001). CTA/CTP (7.9 ± 2.8 mSv) had a significantly lower effective radiation dose than angiography (9.5 ± 5.1 mSv; p = 0.005). The area under the receiver-operating characteristic curve for CTA/CTP (0.82, 95% CI: 0.69 to 0.95) was superior to that for CTA (0.69, 95% CI: 0.57 to 0.82; p < 0.001) in identifying patients requiring stent revascularization. Conclusions Combined coronary CTA and myocardial CTP improves diagnosis of CAD and in-stent restenosis in patients with stents compared with CTA alone. (Coronary Artery Stent Evaluation With 320-Slice Computed Tomography - The CArS 320 Study [CARS-320]; NCT00967876).
AB - Objectives This study sought to determine whether adding myocardial computed tomography perfusion (CTP) to computed tomography angiography (CTA) improves diagnostic performance for coronary stents. Background CTA of coronary stents has been limited by nondiagnostic studies caused by metallic stent material and coronary motion. Methods CTA and CTP were performed in 91 consecutive patients with stents before quantitative coronary angiography, the reference standard for obstructive stenosis (≥50%). If a coronary stent or vessel was nondiagnostic on CTA, adenosine stress CTP in the corresponding myocardial territory was read for combined CTA/CTP. Results Patients had an average of 2.5 ± 1.8 coronary stents (1 to 10), with a diameter of 3.0 ± 0.5 mm. Significantly more patients were nondiagnostic for stent assessment by CTA (22%; mainly due to metal artifacts [75%] or motion [25%]) versus CTP (1%; p < 0.001; severe angina precluded CTP in 1 case). The per-patient diagnostic accuracy of CTA/CTP for stents (87%, 95% confidence interval [CI]: 78% to 93%) was significantly higher than that of CTA alone (71%, 95% CI: 61% to 80%; p < 0.001), mainly because nondiagnostic examinations were significantly reduced (p < 0.001). In the analysis of any coronary artery disease, diagnostic accuracy and nondiagnostic rate were also significantly improved by the addition of CTP (p < 0.001). CTA/CTP (7.9 ± 2.8 mSv) had a significantly lower effective radiation dose than angiography (9.5 ± 5.1 mSv; p = 0.005). The area under the receiver-operating characteristic curve for CTA/CTP (0.82, 95% CI: 0.69 to 0.95) was superior to that for CTA (0.69, 95% CI: 0.57 to 0.82; p < 0.001) in identifying patients requiring stent revascularization. Conclusions Combined coronary CTA and myocardial CTP improves diagnosis of CAD and in-stent restenosis in patients with stents compared with CTA alone. (Coronary Artery Stent Evaluation With 320-Slice Computed Tomography - The CArS 320 Study [CARS-320]; NCT00967876).
KW - computed tomography coronary angiography coronary vessels diagnostic accuracy stents
UR - http://www.scopus.com/inward/record.url?scp=84885453578&partnerID=8YFLogxK
U2 - 10.1016/j.jacc.2013.03.088
DO - 10.1016/j.jacc.2013.03.088
M3 - Article
C2 - 23792193
AN - SCOPUS:84885453578
SN - 0735-1097
VL - 62
SP - 1476
EP - 1485
JO - Journal of the American College of Cardiology
JF - Journal of the American College of Cardiology
IS - 16
ER -