T1 - Comparison of contact radiographed and stained histological sections for osseointegration analysis of dental implants
T2 - an in vivo study
AU - Bissinger, Oliver
AU - Götz, Carolin
AU - Jeschke, Anke
AU - Haller, Bernhard
AU - Wolff, Klaus Dietrich
AU - Kaiser, Pascal
AU - Kolk, Andreas
N1 - Publisher Copyright:
© 2017 Elsevier Inc.
PY - 2018/1
Y1 - 2018/1
N2 - Objectives Histology is still regarded as the gold-standard to determine bone implant contact (BIC) as a parameter representing implant stability. As the further processing of cut slices for contact radiography (CR) to stained and polished histological sections is time consuming and error prone, our aim was to assess agreement between CR and Giemsa-eosin (GE) stained sections with regard to dental implants. Study Design Threaded dental titanium implants (n = 54) from the maxillae of Goettingen minipigs were evaluated. After 28 and 56 days, BIC and the ratio of bone volume to total volume (BV/TV; 1000 μm) were determined on the same sections by using CR and GE staining, and the results were compared. Results Moderate differences for BIC (0.6%; P =.53) and BV/TV (1.3%; P =.01) between the methods were determined, in which CR overestimated BIC and BV/TV. A strong correlation was seen between the modalities concerning BIC (28 days: r = 0.84; 56 days: r = 0.85; total: r = 0.85) and BV/TV (r = 0.96; r = 0.94; r = 0.96; all: P <.0001). Conclusions CR enabled determination of the bone-to-implant interface in comparison with GE-stained sections. BIC and BV/TV were slightly overestimated but correlated strongly between the methods. Therefore, if BIC and BV/TV are sufficient endpoints, CR is adequate and no further preparation and staining are necessary.
AB - Objectives Histology is still regarded as the gold-standard to determine bone implant contact (BIC) as a parameter representing implant stability. As the further processing of cut slices for contact radiography (CR) to stained and polished histological sections is time consuming and error prone, our aim was to assess agreement between CR and Giemsa-eosin (GE) stained sections with regard to dental implants. Study Design Threaded dental titanium implants (n = 54) from the maxillae of Goettingen minipigs were evaluated. After 28 and 56 days, BIC and the ratio of bone volume to total volume (BV/TV; 1000 μm) were determined on the same sections by using CR and GE staining, and the results were compared. Results Moderate differences for BIC (0.6%; P =.53) and BV/TV (1.3%; P =.01) between the methods were determined, in which CR overestimated BIC and BV/TV. A strong correlation was seen between the modalities concerning BIC (28 days: r = 0.84; 56 days: r = 0.85; total: r = 0.85) and BV/TV (r = 0.96; r = 0.94; r = 0.96; all: P <.0001). Conclusions CR enabled determination of the bone-to-implant interface in comparison with GE-stained sections. BIC and BV/TV were slightly overestimated but correlated strongly between the methods. Therefore, if BIC and BV/TV are sufficient endpoints, CR is adequate and no further preparation and staining are necessary.
UR - http://www.scopus.com/inward/record.url?scp=85032227992&partnerID=8YFLogxK
U2 - 10.1016/j.oooo.2017.06.118
DO - 10.1016/j.oooo.2017.06.118
M3 - Article
C2 - 29079369
AN - SCOPUS:85032227992
SN - 2212-4403
VL - 125
SP - 20
EP - 26
JO - Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
JF - Oral Surgery, Oral Medicine, Oral Pathology and Oral Radiology
IS - 1
ER -