TY - JOUR
T1 - Combination of asymmetric flow field-flow fractionation (AF4) and total-reflexion X-ray fluorescence analysis (TXRF) for determination of heavy metals associated with colloidal humic substances
AU - Exner, A.
AU - Theisen, M.
AU - Panne, U.
AU - Niessner, R.
N1 - Funding Information:
Acknowledgements We thank the “Bayerisches Staatsministe-rium für Landesentwicklung und Umweltfragen” for financial support.
PY - 2000
Y1 - 2000
N2 - To assess the structural variability of colloidal humic substances and the associated heavy metals an off-line coupling of asymmetric flow field-flow fractionation (AF4) with total-reflection X-ray fluorescence analysis (TXRF) is presented. AF4 allows a rather gentle separation of colloids with a minimum of interference and artifacts as no shear forces, drying, or interactions with a stationary phase are involved. After a calibration with suitable polymer particles of known molecular weight, the molecular weight distribution of colloidal humic substances between 1 and 103 kDa can be assessed with AF4. The combination with TXRF permits a simultaneous multielement analysis after preconcentration of samples on the AF4 channel using an optimized buffer. The analysis of seepage and sewage water sample and a sewage sludge sample yielded continuous distributions of the molecular weight and the associated heavy metals. The potential of AF4-TXRF coupling for the study of metal ion exchange equilibria with colloids was demonstrated by spiking seepage water with various heavy metals and subsequent AF4-TXRF analysis of the heavy metals bound to the colloidal fraction (Cu, Cr, Zn, Ni, Co).
AB - To assess the structural variability of colloidal humic substances and the associated heavy metals an off-line coupling of asymmetric flow field-flow fractionation (AF4) with total-reflection X-ray fluorescence analysis (TXRF) is presented. AF4 allows a rather gentle separation of colloids with a minimum of interference and artifacts as no shear forces, drying, or interactions with a stationary phase are involved. After a calibration with suitable polymer particles of known molecular weight, the molecular weight distribution of colloidal humic substances between 1 and 103 kDa can be assessed with AF4. The combination with TXRF permits a simultaneous multielement analysis after preconcentration of samples on the AF4 channel using an optimized buffer. The analysis of seepage and sewage water sample and a sewage sludge sample yielded continuous distributions of the molecular weight and the associated heavy metals. The potential of AF4-TXRF coupling for the study of metal ion exchange equilibria with colloids was demonstrated by spiking seepage water with various heavy metals and subsequent AF4-TXRF analysis of the heavy metals bound to the colloidal fraction (Cu, Cr, Zn, Ni, Co).
UR - http://www.scopus.com/inward/record.url?scp=0034139525&partnerID=8YFLogxK
U2 - 10.1007/s002160050050
DO - 10.1007/s002160050050
M3 - Article
C2 - 11225669
AN - SCOPUS:0034139525
SN - 0937-0633
VL - 366
SP - 254
EP - 259
JO - Fresenius' Journal of Analytical Chemistry
JF - Fresenius' Journal of Analytical Chemistry
IS - 3
ER -