Cement-Augmented Carbon Fiber–Reinforced Pedicle Screw Instrumentation for Spinal Metastases: Safety and Efficacy

Arthur Wagner, Elena Haag, Ann Kathrin Joerger, Jens Gempt, Sandro M. Krieg, Maria Wostrack, Bernhard Meyer

Research output: Contribution to journalArticlepeer-review

20 Scopus citations

Abstract

Objective: To investigate the complication rates and long-term implant failure rates in a monocentric study of a consecutive cohort of patients with thoracolumbar spinal metastases after posterior instrumentation with a fenestrated carbon fiber–reinforced poly-ether-ether-ketone (CFRP) pedicle screw system. Methods: We retrospectively reviewed demographics, Karnofsky Performance Status Scale scores, complications, and implant failure rates. Results: Between June 2016 and November 2019, 51 consecutive patients underwent cement-augmented CFRP pedicle screw instrumentation at our institution. Mean age was 68 years (standard deviation 10.5), the median preoperative Karnofsky Performance Status Scale of 80 increased to 90 postoperatively (P = 0.471). Most common primary entities were breast (25.5%), lung (15.7%), and prostate (13.7%) cancers. Of 428 placed screws, 293 (68.5%) were augmented with polymethylmethacrylate, a mean 6 per patient (standard deviation ±2). Screws were inserted via a minimally invasive system technique in 54.9% of cases. In total, 11.8% of patients had immediate postoperative sequelae related to the cement. Pulmonary cement embolisms were noted in 3 patients, 2 had paravertebral extravasation, and 1 had an embolism into a segmental artery. Of these 6, 2 patients with pulmonary embolisms reported related symptoms. Follow-up was available for 80.4%. After a mean 9.8 months, screw loosening was noted in 11.8% of cases on computed tomography, although it was asymptomatic in all but 1 patient. Screw pull-out did not occur. Neither cement-related (P = 0.353) nor general complication rates (P = 0.507) differed significantly between open and minimally invasive system techniques. Conclusions: Percutaneous cement-augmented CFRP pedicle screw instrumentation facilitates artifact-reduced postoperative imaging, while maintaining a risk profile and implant failure rates comparable to conventional metallic instrumentation.

Original languageEnglish
Pages (from-to)e536-e546
JournalWorld Neurosurgery
Volume154
DOIs
StatePublished - Oct 2021

Keywords

  • Carbon
  • Dement augmentation
  • Instrumentation
  • PEEK
  • Spinal metastasis

Fingerprint

Dive into the research topics of 'Cement-Augmented Carbon Fiber–Reinforced Pedicle Screw Instrumentation for Spinal Metastases: Safety and Efficacy'. Together they form a unique fingerprint.

Cite this