TY - GEN
T1 - Cardiac MR segmentation from undersampled k-space using deep latent representation learning
AU - Schlemper, Jo
AU - Oktay, Ozan
AU - Bai, Wenjia
AU - Castro, Daniel C.
AU - Duan, Jinming
AU - Qin, Chen
AU - Hajnal, Jo V.
AU - Rueckert, Daniel
N1 - Publisher Copyright:
© Springer Nature Switzerland AG 2018.
PY - 2018
Y1 - 2018
N2 - Reconstructing magnetic resonance imaging (MRI) from undersampled k-space enables the accelerated acquisition of MRI but is a challenging problem. However, in many diagnostic scenarios, perfect reconstructions are not necessary as long as the images allow clinical practitioners to extract clinically relevant parameters. In this work, we present a novel deep learning framework for reconstructing such clinical parameters directly from undersampled data, expanding on the idea of application-driven MRI. We propose two deep architectures, an end-to-end synthesis network and a latent feature interpolation network, to predict cardiac segmentation maps from extremely undersampled dynamic MRI data, bypassing the usual image reconstruction stage altogether. We perform a large-scale simulation study using UK Biobank data containing nearly 1000 test subjects and show that with the proposed approaches, an accurate estimate of clinical parameters such as ejection fraction can be obtained from fewer than 10 k-space lines per time-frame.
AB - Reconstructing magnetic resonance imaging (MRI) from undersampled k-space enables the accelerated acquisition of MRI but is a challenging problem. However, in many diagnostic scenarios, perfect reconstructions are not necessary as long as the images allow clinical practitioners to extract clinically relevant parameters. In this work, we present a novel deep learning framework for reconstructing such clinical parameters directly from undersampled data, expanding on the idea of application-driven MRI. We propose two deep architectures, an end-to-end synthesis network and a latent feature interpolation network, to predict cardiac segmentation maps from extremely undersampled dynamic MRI data, bypassing the usual image reconstruction stage altogether. We perform a large-scale simulation study using UK Biobank data containing nearly 1000 test subjects and show that with the proposed approaches, an accurate estimate of clinical parameters such as ejection fraction can be obtained from fewer than 10 k-space lines per time-frame.
UR - http://www.scopus.com/inward/record.url?scp=85054094623&partnerID=8YFLogxK
U2 - 10.1007/978-3-030-00928-1_30
DO - 10.1007/978-3-030-00928-1_30
M3 - Conference contribution
AN - SCOPUS:85054094623
SN - 9783030009274
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 259
EP - 267
BT - Medical Image Computing and Computer Assisted Intervention – MICCAI 2018 - 21st International Conference, 2018, Proceedings
A2 - Schnabel, Julia A.
A2 - Davatzikos, Christos
A2 - Alberola-López, Carlos
A2 - Fichtinger, Gabor
A2 - Frangi, Alejandro F.
PB - Springer Verlag
T2 - 21st International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2018
Y2 - 16 September 2018 through 20 September 2018
ER -