TY - JOUR
T1 - Bicuspid aortic valve anatomy and relationship with devices
T2 - The Bavard multicenter Registry: A European picture of contemporary multidetector computed tomography sizing for bicuspid valves
AU - Tchetche, Didier
AU - De Biase, Chiara
AU - Van Gils, Lennart
AU - Parma, Radoslaw
AU - Ochala, Andrzej
AU - Lefevre, Thierry
AU - Hovasse, Thomas
AU - De Backer, Ole
AU - Sondergaard, Lars
AU - Bleiziffer, Sabine
AU - Lange, Rudiger
AU - Kornowski, Ran
AU - Landes, Uri
AU - Norgaard, Bjarne Linde
AU - Biasco, Luigi
AU - Philippart, Raphaël
AU - De Nicolas, Javier Molina Martin
AU - Mylotte, Darren
AU - Lemee, Caroline
AU - Dumonteil, Nicolas
AU - Van Mieghem, Nicolas M.
N1 - Publisher Copyright:
© 2019 American Heart Association, Inc.
PY - 2019
Y1 - 2019
N2 - BACKGROUND: Sizing for transcatheter aortic valve implantation in bicuspid aortic valves (BAV) remains controversial. METHODS AND RESULTS: The aim of the BAVARD (Bicuspid Aortic Valve Anatomy and Relationship With Devices) retrospective registry is to capture the sizing ratios used for transcatheter aortic valve implantation in BAV and analyze the second-generation prostheses geometry postimplantation. About 101 patients with BAV along with available pre- and post-transcatheter aortic valve implantation multidetector computed tomography were compared with 88 tricuspid aortic valves (TAV) patients. Preprocedural multidetector computed tomography diagnosed type 0 and type 1 BAV in, respectively, 12.9% and 86.1 % of BAV. At baseline, the ellipticity index was similar between BAV and TAV patients: 1.2±0.1 versus 1.2±0.1, P=0.09. The mean annular oversizing was, respectively, 1.14±0.04 and 1.04±0.04, P<0.001, in TAV and BAV patients. The mean prosthesis intercommissural distance, ratio was 1.03±0.1. The mean diameter of the prostheses at the annulus matched the mean perimeter-derived diameter of the aortic annulus at baseline with TAV (23.3±2.2 versus 23.6±1.9, P=0.4) and was smaller with BAV (24±2.8 versus 26.8±3.1, P<0.01), confirming 11% underexpansion in BAV. Finally, in situ, prosthesis diameter and ellipticity followed the same pattern, with stable values from the distal edge to 12 mm above, in both groups. CONCLUSIONS: Second-generation prostheses similarly reshape the aortic annulus in TAV and BAV. Prostheses keep consistent diameters from distal edge to 12 mm in TAV and BAV. Prosthesis underexpansion is constantly observed in BAV. Annular-based sizing is accurate in BAV with minimal oversizing. The intercommissural distance, 4 mm above the annulus, could be integrated in gray zones.
AB - BACKGROUND: Sizing for transcatheter aortic valve implantation in bicuspid aortic valves (BAV) remains controversial. METHODS AND RESULTS: The aim of the BAVARD (Bicuspid Aortic Valve Anatomy and Relationship With Devices) retrospective registry is to capture the sizing ratios used for transcatheter aortic valve implantation in BAV and analyze the second-generation prostheses geometry postimplantation. About 101 patients with BAV along with available pre- and post-transcatheter aortic valve implantation multidetector computed tomography were compared with 88 tricuspid aortic valves (TAV) patients. Preprocedural multidetector computed tomography diagnosed type 0 and type 1 BAV in, respectively, 12.9% and 86.1 % of BAV. At baseline, the ellipticity index was similar between BAV and TAV patients: 1.2±0.1 versus 1.2±0.1, P=0.09. The mean annular oversizing was, respectively, 1.14±0.04 and 1.04±0.04, P<0.001, in TAV and BAV patients. The mean prosthesis intercommissural distance, ratio was 1.03±0.1. The mean diameter of the prostheses at the annulus matched the mean perimeter-derived diameter of the aortic annulus at baseline with TAV (23.3±2.2 versus 23.6±1.9, P=0.4) and was smaller with BAV (24±2.8 versus 26.8±3.1, P<0.01), confirming 11% underexpansion in BAV. Finally, in situ, prosthesis diameter and ellipticity followed the same pattern, with stable values from the distal edge to 12 mm above, in both groups. CONCLUSIONS: Second-generation prostheses similarly reshape the aortic annulus in TAV and BAV. Prostheses keep consistent diameters from distal edge to 12 mm in TAV and BAV. Prosthesis underexpansion is constantly observed in BAV. Annular-based sizing is accurate in BAV with minimal oversizing. The intercommissural distance, 4 mm above the annulus, could be integrated in gray zones.
KW - Aortic valve
KW - Bicuspid
KW - Heart valve diseases
KW - Multidetector computed tomography
KW - Tricuspid valve
UR - http://www.scopus.com/inward/record.url?scp=85059797781&partnerID=8YFLogxK
U2 - 10.1161/CIRCINTERVENTIONS.118.007107
DO - 10.1161/CIRCINTERVENTIONS.118.007107
M3 - Article
C2 - 30626202
AN - SCOPUS:85059797781
SN - 1941-7640
VL - 12
JO - Circulation: Cardiovascular Interventions
JF - Circulation: Cardiovascular Interventions
IS - 1
M1 - e007107
ER -