T1 - Automatic detection and quantification of hippocampal atrophy on MRI in temporal lobe epilepsy
T2 - A proof-of-principle study
AU - Hammers, Alexander
AU - Heckemann, Rolf
AU - Koepp, Matthias J.
AU - Duncan, John S.
AU - Hajnal, Jo V.
AU - Rueckert, Daniel
AU - Aljabar, Paul
N1 - Funding Information:
This work was performed during grant funding from the Medical Research Council to Dr Hammers (G108/585). The funding source had no role in this study. We thank our healthy and patient volunteers, our colleagues at the National Hospital for Neurology and Neurosurgery, Queen Square, for referring patients and for performing the surgical resections, and our colleagues at the National Society for Epilepsy for performing and transferring the MRI scans.
PY - 2007/5/15
Y1 - 2007/5/15
N2 - In temporal lobe epilepsy (TLE), hippocampal atrophy (HA) is a marker of poor prognosis regarding seizure remission, but predicts success of anterior temporal lobe resection. Manual quantification of HA on MRI is time-consuming and limited by investigator availability. Normal ranges of hippocampal volumes, both in absolute terms and relative to intracranial volume, and of hippocampal asymmetry were defined using an automatic label propagation and decision fusion technique based on thirty manually derived atlases of healthy controls. Manual test-retest reliability and overlaps of automatically and manually determined hippocampal volumes were quantified with similarity indices (SIs). Correct clinical identification of ipsilateral HA, and contralaterally normal hippocampal volumes, was determined in nine patients with histologically confirmed hippocampal sclerosis in terms of volumes and asymmetry indices (AIs) for standard statistical thresholds and with receiver operating characteristic (ROC) analysis. Manual test-retest reliability was very high, with SIs between 0.87 and 0.90. Manual and automatic hippocampus labels overlapped with a SI of 0.83 on the unaffected but with 0.76 on the atrophic side. Accuracy was higher for less atrophic hippocampi. The automatic method correctly identified 6/9 HAs in terms of absolute volume, 7/9 in terms of relative volume at a standard 2 SD threshold, and 9/9 for AIs. ROC-determined thresholds allowed clinically desirable correct identification of all HAs (100% sensitivity) with 85-100% specificity for volumes, and 100% specificity for AIs. The method has the potential to automatically detect unilateral HA, but further work is needed to determine its performance in detecting clinically important bilateral disease.
AB - In temporal lobe epilepsy (TLE), hippocampal atrophy (HA) is a marker of poor prognosis regarding seizure remission, but predicts success of anterior temporal lobe resection. Manual quantification of HA on MRI is time-consuming and limited by investigator availability. Normal ranges of hippocampal volumes, both in absolute terms and relative to intracranial volume, and of hippocampal asymmetry were defined using an automatic label propagation and decision fusion technique based on thirty manually derived atlases of healthy controls. Manual test-retest reliability and overlaps of automatically and manually determined hippocampal volumes were quantified with similarity indices (SIs). Correct clinical identification of ipsilateral HA, and contralaterally normal hippocampal volumes, was determined in nine patients with histologically confirmed hippocampal sclerosis in terms of volumes and asymmetry indices (AIs) for standard statistical thresholds and with receiver operating characteristic (ROC) analysis. Manual test-retest reliability was very high, with SIs between 0.87 and 0.90. Manual and automatic hippocampus labels overlapped with a SI of 0.83 on the unaffected but with 0.76 on the atrophic side. Accuracy was higher for less atrophic hippocampi. The automatic method correctly identified 6/9 HAs in terms of absolute volume, 7/9 in terms of relative volume at a standard 2 SD threshold, and 9/9 for AIs. ROC-determined thresholds allowed clinically desirable correct identification of all HAs (100% sensitivity) with 85-100% specificity for volumes, and 100% specificity for AIs. The method has the potential to automatically detect unilateral HA, but further work is needed to determine its performance in detecting clinically important bilateral disease.
UR - http://www.scopus.com/inward/record.url?scp=34247358222&partnerID=8YFLogxK
U2 - 10.1016/j.neuroimage.2007.02.031
DO - 10.1016/j.neuroimage.2007.02.031
M3 - Article
C2 - 17428687
AN - SCOPUS:34247358222
SN - 1053-8119
VL - 36
SP - 38
EP - 47
JO - NeuroImage
JF - NeuroImage
IS - 1
ER -