Skip to main navigation Skip to search Skip to main content

Automatic correction of registration errors in surgical navigation systems

  • Wolfgang Wittmann
  • , Thomas Wenger
  • , Benjamin Zaminer
  • , Tim C. Lueth
  • Technical University of Munich
  • Ergosurg GmbH
  • University of Leipzig

Research output: Contribution to journalArticlepeer-review

22 Scopus citations

Abstract

Surgical navigation systems are used widely among all fields of modern medicine, including, but not limited to ENT- and maxillofacial surgery. As a fundamental prerequisite for image-guided surgery, intraoperative registration, which maps image to patient coordinates, has been subject to many studies and developments. While registration methods have evolved from invasive procedures like fixed stereotactic frames and implanted fiducial markers toward surface-based registration and noninvasive markers fixed to the patients skin, even the most sophisticated registration techniques produce an imperfect result. Due to errors introduced during the registration process, the projection of navigated instruments into image data deviates up to several millimeter from the actual position, depending on the applied registration method and the distance between the instrument and the fiducial markers. We propose a method that allows to automatically and continually improve registration accuracy during intraoperative navigation after the actual registration process has been completed. The projections of navigated instruments into image data are inspected and validated by the navigation software. Errors in image-to-patient registration are identified by calculating intersections between the virtual instruments axes and surfaces of hard bone tissue extracted from the patients image data. The information gained from the identification of such registration errors is then used to improve registration accuracy by adding an additional pair of registration points at every location where an error has been detected. The proposed method was integrated into a surgical navigation system based on paired points registration with anatomical landmarks. Experiments were conducted, where registrations with deliberately misplaced point pairs were corrected with automatic error correction. Results showed an improvement in registration quality in all cases.

Original languageEnglish
Article number5963707
Pages (from-to)2922-2930
Number of pages9
JournalIEEE Transactions on Biomedical Engineering
Volume58
Issue number10 PART 1
DOIs
StatePublished - Oct 2011

Keywords

  • Automatic matching
  • image-guided surgery
  • point-based registration
  • surface registration
  • surgical navigation

Fingerprint

Dive into the research topics of 'Automatic correction of registration errors in surgical navigation systems'. Together they form a unique fingerprint.

Cite this