TY - JOUR
T1 - Automated microextraction sample preparation coupled on-line to FT-ICR-MS
T2 - Application to desalting and concentration of river and marine dissolved organic matter
AU - Morales-Cid, Gabriel
AU - Gebefugi, Istvan
AU - Kanawati, Basem
AU - Harir, Mourad
AU - Hertkorn, Norbert
AU - Rosselló-Mora, Ramón
AU - Schmitt-Kopplin, Philippe
N1 - Funding Information:
Acknowledgment G. Morales-Cid wishes to thank the Spain’s Ministry of Innovation and Science for the award of a FPI fellowship (Grant BES-2005-10603) to work with the German colleagues and the additional economic support within the mobility program. Dr. Marianna Lucio is thanked for the help in sampling the harbor sample.
PY - 2009
Y1 - 2009
N2 - Sample preparation procedures are in most cases sample- and time-consuming and commonly require the use of a large amount of solvents. Automation in this regard can optimize the minimal-needed injection volume and the solvent consumption will be efficiently reduced. A new fully automated sample desalting and pre-concentration technique employing microextraction by packed sorbents (MEPS) cartridges is implemented and coupled to an ion cyclotron resonance Fourier-transform mass spectrometer (ICR-FT/MS). The performance of non-target mass spectrometric analysis is compared for the automated versus off-line sample preparation for several samples of aqueous natural organic matter. This approach can be generalized for any metabolite profiling or metabolome analysis of biological materials but was optimized herein using a well characterized but highly complex organic mixture: a surface water and its well-characterized natural organic matter and a marine sample having a highly salt charge and enabling to validate the presented automatic system for salty samples. The analysis of Suwannee River water showed selective C18-MEPS enrichment of chemical signatures with average H/C and O/C elemental ratios and loss of both highly polar and highly aromatic structures from the original sample. Automated on-line application to marine samples showed desalting and different chemical signatures from surface to bottom water. Relative comparison of structural footprints with the C18-concentration/desalting procedure however enabled to demonstrate that the surface water film was more concentrated in surface-active components of natural (fatty acids) and anthropogenic origin (sulfur-containing surfactants). Overall, the relative standard deviation distribution in terms of peak intensity was improved by automating the proposed on-line method.
AB - Sample preparation procedures are in most cases sample- and time-consuming and commonly require the use of a large amount of solvents. Automation in this regard can optimize the minimal-needed injection volume and the solvent consumption will be efficiently reduced. A new fully automated sample desalting and pre-concentration technique employing microextraction by packed sorbents (MEPS) cartridges is implemented and coupled to an ion cyclotron resonance Fourier-transform mass spectrometer (ICR-FT/MS). The performance of non-target mass spectrometric analysis is compared for the automated versus off-line sample preparation for several samples of aqueous natural organic matter. This approach can be generalized for any metabolite profiling or metabolome analysis of biological materials but was optimized herein using a well characterized but highly complex organic mixture: a surface water and its well-characterized natural organic matter and a marine sample having a highly salt charge and enabling to validate the presented automatic system for salty samples. The analysis of Suwannee River water showed selective C18-MEPS enrichment of chemical signatures with average H/C and O/C elemental ratios and loss of both highly polar and highly aromatic structures from the original sample. Automated on-line application to marine samples showed desalting and different chemical signatures from surface to bottom water. Relative comparison of structural footprints with the C18-concentration/desalting procedure however enabled to demonstrate that the surface water film was more concentrated in surface-active components of natural (fatty acids) and anthropogenic origin (sulfur-containing surfactants). Overall, the relative standard deviation distribution in terms of peak intensity was improved by automating the proposed on-line method.
KW - ICR-FT/MS
KW - MEPS
KW - Marine water samples
KW - On-line water analysis
KW - Suwannee river
UR - http://www.scopus.com/inward/record.url?scp=70349611824&partnerID=8YFLogxK
U2 - 10.1007/s00216-009-3025-0
DO - 10.1007/s00216-009-3025-0
M3 - Article
C2 - 19685041
AN - SCOPUS:70349611824
SN - 1618-2642
VL - 395
SP - 797
EP - 807
JO - Analytical and Bioanalytical Chemistry
JF - Analytical and Bioanalytical Chemistry
IS - 3
ER -