Angiographic and clinical outcomes of STEMI patients treated with bioresorbable or metallic everolimus-eluting stents: A pooled analysis of individual patient data

Salvatore Cassese, Yuki Katagiri, Robert A. Byrne, Salvatore Brugaletta, Fernando Alfonso, Lorenz Räber, Michael Maeng, Andres Iniguez, Evgeny Kretov, Yoshinobu Onuma, Michael Joner, Manel Sabaté, Karl Ludwig Laugwitz, Stephan Windecker, Adnan Kastrati, Patrick W. Serruys

Research output: Contribution to journalArticlepeer-review

11 Scopus citations

Abstract

Aims: Bioresorbable scaffolds (BRS) were conceived to ensure transient coronary artery support during antiproliferative drug delivery. However, the Absorb everolimus-eluting bioresorbable scaffold was found to be inferior to everolimus-eluting metallic stents (EES) in moderately complex coronary anatomies. We sought to investigate whether the Absorb represents a valuable option for the percutaneous treatment of patients with ST-elevation myocardial infarction (STEMI). Methods and results: We pooled the individual patient data of two randomised trials specifically designed to investigate the performance of Absorb versus EES in patients with acute myocardial infarction (MI). The primary outcome was lesion (in-segment) diameter stenosis at angiographic follow-up. The main secondary outcome was the device-oriented composite endpoint (DOCE) of cardiac death, target vessel MI and target lesion revascularisation at one year. A total of 388 patients with STEMI were allocated to Absorb (n=227) or EES (n=161). Angiographic follow-up at one year was available for 332 (85.6%) patients. Lesion diameter stenosis was comparable between Absorb and EES (22.8±9.8% versus 23.6±11.2%; mean difference -0.8%, 95% confidence interval [CI]: -3.18-1.48, p=0.47). DOCE occurred in 21 patients at one year, with similar distribution between the Absorb and EES groups (5.3% versus 5.6%; hazard ratio 0.95, 95% CI: 0.40-2.26, p=0.91). Conclusions: This pooled analysis provides evidence for a comparable angiographic performance and suggests similar clinical performance of Absorb and EES in STEMI patients undergoing percutaneous revascularisation. The long-term durability of Absorb and the extent to which newer BRS platforms might have a potential role in STEMI deserve further investigation.

Original languageEnglish
Pages (from-to)1451-1457
Number of pages7
JournalEuroIntervention
Volume14
Issue number16
DOIs
StatePublished - Mar 2020

Keywords

  • Bioresorbable scaffolds
  • Drug-eluting stent
  • STEMI

Fingerprint

Dive into the research topics of 'Angiographic and clinical outcomes of STEMI patients treated with bioresorbable or metallic everolimus-eluting stents: A pooled analysis of individual patient data'. Together they form a unique fingerprint.

Cite this