Abstract
A new beam line and injector deck for AMS measurements have been built at the 8 MV tandem accelerator of the National Institute of Nuclear Physics and Engineering, Bucharest, Romania. The main components on the low-energy side are a high-current cesium sputter source, a 90° injection magnet and a pre-acceleration stage. At the high-energy side the beam line is achromatic, consisting of two 90° analysing magnets with mass energy product 120 MeV amu and a gas-filled ionization chamber. The system will be complete with a Wien filter and a multi-anode gas detector with time-of-flight discrimination. Presently, the AMS facility is undergoing tests and routine measurements are expected to start soon.
| Original language | English |
|---|---|
| Pages (from-to) | 29-33 |
| Number of pages | 5 |
| Journal | Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms |
| Volume | 172 |
| Issue number | 1-4 |
| DOIs | |
| State | Published - 2000 |
Keywords
- New AMS facilities
Fingerprint
Dive into the research topics of 'AMS at the National Institute of Nuclear Physics and Engineering in Bucharest'. Together they form a unique fingerprint.Cite this
- APA
- Author
- BIBTEX
- Harvard
- Standard
- RIS
- Vancouver