TY - JOUR
T1 - Advanced phase-contrast imaging using a grating interferometer
AU - McDonald, Samuel Alan
AU - Marone, Federica
AU - Hintermüller, Christoph
AU - Mikuljan, Gordan
AU - David, Christian
AU - Pfeiffer, Franz
AU - Stampanoni, Marco
PY - 2009
Y1 - 2009
N2 - Phase-sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging, and therefore new and otherwise inaccessible information. Differential phase-contrast (DPC) imaging, which uses a grating interferometer and a phase-stepping technique, has been integrated into TOMCAT, a beamline dedicated to tomographic microscopy and coherent radiology experiments at the Swiss Light Source. Developments have been made focusing on the fast acquisition and post-processing of data to enable a high-throughput of samples, with obvious advantages, also through increasing the efficiency of the detecting system, of helping to reduce radiation dose imparted to the sample. A novel aquarium design allows a vertical rotation axis below the sample with measurements performed in aqueous environment. Optimization of the data acquisition procedure enables a full phase volume (1024 1024 pixels 1000 projections 9 phase steps, i.e. 9000 projections in total) to be acquired in 20 min (with a pixel size of 7.4 m), and the subsequent post-processing has been integrated into the beamline pipeline for sinogram generation. Local DPC tomography allows one to focus with higher magnification on a particular region of interest of a sample without the presence of local tomography reconstruction artifacts. Furthermore, widefield imaging is shown for DPC scans for the first time, enabling the field of view of the imaging system to be doubled for samples that are larger than the magnification allows. A case study is illustrated focusing on the visualization of soft tissue features, and particularly the substantia nigra of a rat brain. Darkfield images, based on local X-ray scattering, can also be extracted from a grating-based DPC scan: an example of the advantages of darkfield contrast is shown and the potential of darkfield X-ray tomography is discussed.
AB - Phase-sensitive X-ray imaging methods can provide substantially increased contrast over conventional absorption-based imaging, and therefore new and otherwise inaccessible information. Differential phase-contrast (DPC) imaging, which uses a grating interferometer and a phase-stepping technique, has been integrated into TOMCAT, a beamline dedicated to tomographic microscopy and coherent radiology experiments at the Swiss Light Source. Developments have been made focusing on the fast acquisition and post-processing of data to enable a high-throughput of samples, with obvious advantages, also through increasing the efficiency of the detecting system, of helping to reduce radiation dose imparted to the sample. A novel aquarium design allows a vertical rotation axis below the sample with measurements performed in aqueous environment. Optimization of the data acquisition procedure enables a full phase volume (1024 1024 pixels 1000 projections 9 phase steps, i.e. 9000 projections in total) to be acquired in 20 min (with a pixel size of 7.4 m), and the subsequent post-processing has been integrated into the beamline pipeline for sinogram generation. Local DPC tomography allows one to focus with higher magnification on a particular region of interest of a sample without the presence of local tomography reconstruction artifacts. Furthermore, widefield imaging is shown for DPC scans for the first time, enabling the field of view of the imaging system to be doubled for samples that are larger than the magnification allows. A case study is illustrated focusing on the visualization of soft tissue features, and particularly the substantia nigra of a rat brain. Darkfield images, based on local X-ray scattering, can also be extracted from a grating-based DPC scan: an example of the advantages of darkfield contrast is shown and the potential of darkfield X-ray tomography is discussed.
KW - Darkfield
KW - Differential phase contrast
KW - Grating interferometry
KW - Synchrotron microtomography
KW - X-ray imaging
UR - http://www.scopus.com/inward/record.url?scp=67651180649&partnerID=8YFLogxK
U2 - 10.1107/S0909049509017920
DO - 10.1107/S0909049509017920
M3 - Article
C2 - 19535872
AN - SCOPUS:67651180649
SN - 0909-0495
VL - 16
SP - 562
EP - 572
JO - Journal of Synchrotron Radiation
JF - Journal of Synchrotron Radiation
IS - 4
ER -