Absence of magnetic field influences on the rate of Ni(CO)4 formation on Ni(100) under various surface conditions

G. Greiner, D. Menzel

Research output: Contribution to journalArticlepeer-review

7 Scopus citations

Abstract

Using UHV techniques and a flow system with continuous monitoring of the reaction rate, we have investigated the rate of Ni(CO)4 formation, R, on Ni(100) in an external magnetic field up to 1000 G, under various surface conditions. No magnetic field effect ( ΔR R < 0.01) has been found under any conditions (clean surface with or without roughness ;precoverage with C, S, Hg; temperatures up to 200°C; different B orientation; darkness or illumination).

Original languageEnglish
Pages (from-to)L510-L512
JournalSurface Science
Volume109
Issue number2
DOIs
StatePublished - 2 Aug 1981

Fingerprint

Dive into the research topics of 'Absence of magnetic field influences on the rate of Ni(CO)4 formation on Ni(100) under various surface conditions'. Together they form a unique fingerprint.