Abstract
The symmetrical rail accelerator has four rails, which are arranged symmetrically around the bore. The opposite rails have the same polarity and the adjacent rails the opposite polarity. In this configuration the radial force acting upon the individual rails is significantly smaller than in a conventional 2-rail configuration and a plasma armature is focussed towards the axis of the barrel. Experimental results indicate a higher efficiency compared to a conventional rail accelerator.
Original language | English |
---|---|
Pages (from-to) | 650-653 |
Number of pages | 4 |
Journal | IEEE Transactions on Magnetics |
Volume | 27 |
Issue number | 1 |
DOIs | |