A Prospective, Randomized Trial of Bioresorbable Polymer Drug-Eluting Stents versus Fully Bioresorbable Scaffolds in Patients Undergoing Coronary Stenting

Jens Wiebe, Robert A. Byrne, Christian Bradaric, Constantin Kuna, Thorsten Kessler, Mathieu Pfleiderer, Sebastian Kufner, Erion Xhepa, Petra Hoppmann, Michael Joner, Heribert Schunkert, Karl Ludwig Laugwitz, Adnan Kastrati, Salvatore Cassese

Research output: Contribution to journalArticlepeer-review

Abstract

Background: The performance of an everolimus-eluting bioresorbable scaffold (BRS) was inferior to an everolimus-eluting metallic drug-eluting stent (DES) with permanent polymer, mainly due the mechanical features of BRS technology. The performance of BRS as compared to metallic DES with bioresorbable polymers remains unstudied. Methods: This prospective, randomized, multicenter, clinical trial enrolled patients who underwent coronary stenting for de novo coronary lesions. Patients were randomly assigned to bioresorbable polymer everolimus-eluting stents (BP-EES) or everolimus-eluting BRS. The primary endpoint was percentage diameter stenosis (in-device) at 6- to 8-month angiographic surveillance. The main secondary endpoint was the device-oriented composite endpoint (DOCE) of cardiac death/target vessel-myocardial infarction/target lesion revascularization assessed after 12 months and 5 years. Results: The trial was prematurely terminated after the enrollment of 117 of 230 patients (BP-EES, n = 60; BRS, n = 57) due to safety issues associated with BRS technology. The primary endpoint of in-device diameter stenosis at angiographic surveillance was 12.5 ± 7.7% with BP-EES versus 19.3 ± 16.5% with BRS (p = 0.01). The DOCE occurred in 5.0% in the BP-EES group versus 12.3% of patients in the BRS group (hazard ratio [HR] 2.48, 95% confidence interval [CI] 0.64–9.58, p = 0.19) after 12 months and in 11.7% in the BP-EES group versus 26.4% of patients in the BRS group (HR 2.38, 95% CI 0.97–5.84, p = 0.06) after 5 years. Conclusions: BP-EES showed superior mid-term angiographic performance compared with BRS. Clinical event rates did not differ significantly between the groups up to 5 years of follow-up. These results should be interpreted with caution in view of the premature discontinuation of the study.

Original languageEnglish
Article number5949
JournalJournal of Clinical Medicine
Volume13
Issue number19
DOIs
StatePublished - Oct 2024

Keywords

  • drug-eluting stent
  • percutaneous coronary intervention
  • scaffold

Fingerprint

Dive into the research topics of 'A Prospective, Randomized Trial of Bioresorbable Polymer Drug-Eluting Stents versus Fully Bioresorbable Scaffolds in Patients Undergoing Coronary Stenting'. Together they form a unique fingerprint.

Cite this