N2 - Decreased stride length is a highly relevant characteristic of the gait in patients with Parkinson's disease (PD). In this paper, a novel wearable laser device for stride length regulation is presented. The device is mounted to one foot and can project a red laser light strip to the floor as a visual cue for the other foot. In the experiment twelve healthy volunteers walked a 20 m straight walkway wearing the system on both feet. As an objective result, the stride length regulation reached an accuracy of 96.1±2.5 (94.0±3.5) % for a pre-defined stride length λdef= 55 (65) cm. The subjective evaluation by the participants using a questionnaire revealed that the visual cue projected from the laser device was considered a stable signal that did not shake during walking. 6 of 12 participants felt that this device was not interfering with their gait, 3 of 12 judged this aspect neutrally, and 3 of 12 considered it somehow bothersome.
AB - Decreased stride length is a highly relevant characteristic of the gait in patients with Parkinson's disease (PD). In this paper, a novel wearable laser device for stride length regulation is presented. The device is mounted to one foot and can project a red laser light strip to the floor as a visual cue for the other foot. In the experiment twelve healthy volunteers walked a 20 m straight walkway wearing the system on both feet. As an objective result, the stride length regulation reached an accuracy of 96.1±2.5 (94.0±3.5) % for a pre-defined stride length λdef= 55 (65) cm. The subjective evaluation by the participants using a questionnaire revealed that the visual cue projected from the laser device was considered a stable signal that did not shake during walking. 6 of 12 participants felt that this device was not interfering with their gait, 3 of 12 judged this aspect neutrally, and 3 of 12 considered it somehow bothersome.
UR - http://www.scopus.com/inward/record.url?scp=84886491331&partnerID=8YFLogxK
U2 - 10.1109/EMBC.2013.6610893
DO - 10.1109/EMBC.2013.6610893
M3 - Conference contribution
AN - SCOPUS:84886491331
SN - 9781457702167
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 5895
EP - 5898
BT - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
T2 - 2013 35th Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBC 2013
Y2 - 3 July 2013 through 7 July 2013
ER -