TY - JOUR
T1 - A Low Residual Pressure Gradient Yields Excellent Long-Term Outcome After Percutaneous Pulmonary Valve Implantation
AU - Georgiev, Stanimir
AU - Ewert, Peter
AU - Tanase, Daniel
AU - Hess, John
AU - Hager, Alfred
AU - Cleuziou, Julie
AU - Meierhofer, Christian
AU - Eicken, Andreas
N1 - Publisher Copyright:
© 2019 American College of Cardiology Foundation
PY - 2019/8/26
Y1 - 2019/8/26
N2 - Objectives: The aim of this study was to report long-term outcomes after percutaneous pulmonary valve implantation (PPVI). Background: Excellent short- and mid-term results after PPVI for right ventricular outflow tract (RVOT) dysfunction have been reported. Data on long-term results after PPVI are scarce. Methods: All 226 patients treated with PPVI at a single institution were prospectively enrolled in a database and included in the study. Follow-up information regarding outcomes was collected. Risk-factor analysis for death and reinterventions was performed. Results: Follow-up data (up to 11 years) were available in 96% of the patients. At the end of the study period, 219 patients (92.8%) still lived with the initially implanted valve. Seven patients died, 2 of them from procedure-related complications. Seventeen patients (7.2%) needed valve replacement surgically (n = 11) or percutaneously (n = 6) for infectious endocarditis (n = 10) or valve degeneration (n = 7). In the remaining patients, the valves retained excellent function, and right ventricular dimensions and exercise capacity improved. A post-interventional RVOT gradient >15 mm Hg was a risk factor for death (hazard ratio: 7.57; 95% confidence interval: 1.26 to 45.38; p = 0.027) and for valve failure (hazard ratio: 3.76; 95% confidence interval: 1.43 to 9.93; p = 0.007). The best outcome was achieved with RVOT pre-stenting and a post-interventional gradient <15 mm Hg, resulting in an estimated event-free survival rate of 88% at 10 years. Conclusions: Patients after PPVI have excellent long-term outcomes. Right ventricular volumes, function, and exercise capacity improve significantly. A residual RVOT gradient <15 mm Hg was associated with the best outcome.
AB - Objectives: The aim of this study was to report long-term outcomes after percutaneous pulmonary valve implantation (PPVI). Background: Excellent short- and mid-term results after PPVI for right ventricular outflow tract (RVOT) dysfunction have been reported. Data on long-term results after PPVI are scarce. Methods: All 226 patients treated with PPVI at a single institution were prospectively enrolled in a database and included in the study. Follow-up information regarding outcomes was collected. Risk-factor analysis for death and reinterventions was performed. Results: Follow-up data (up to 11 years) were available in 96% of the patients. At the end of the study period, 219 patients (92.8%) still lived with the initially implanted valve. Seven patients died, 2 of them from procedure-related complications. Seventeen patients (7.2%) needed valve replacement surgically (n = 11) or percutaneously (n = 6) for infectious endocarditis (n = 10) or valve degeneration (n = 7). In the remaining patients, the valves retained excellent function, and right ventricular dimensions and exercise capacity improved. A post-interventional RVOT gradient >15 mm Hg was a risk factor for death (hazard ratio: 7.57; 95% confidence interval: 1.26 to 45.38; p = 0.027) and for valve failure (hazard ratio: 3.76; 95% confidence interval: 1.43 to 9.93; p = 0.007). The best outcome was achieved with RVOT pre-stenting and a post-interventional gradient <15 mm Hg, resulting in an estimated event-free survival rate of 88% at 10 years. Conclusions: Patients after PPVI have excellent long-term outcomes. Right ventricular volumes, function, and exercise capacity improve significantly. A residual RVOT gradient <15 mm Hg was associated with the best outcome.
KW - outcome
KW - percutaneous pulmonary valve implantation
KW - reinterventions
KW - survival
UR - http://www.scopus.com/inward/record.url?scp=85070406818&partnerID=8YFLogxK
U2 - 10.1016/j.jcin.2019.03.037
DO - 10.1016/j.jcin.2019.03.037
M3 - Article
C2 - 31202951
AN - SCOPUS:85070406818
SN - 1936-8798
VL - 12
SP - 1594
EP - 1603
JO - JACC: Cardiovascular Interventions
JF - JACC: Cardiovascular Interventions
IS - 16