TY - GEN
T1 - 3D stent recovery from one x-ray projection
AU - Demirci, Stefanie
AU - Bigdelou, Ali
AU - Wang, Lejing
AU - Wachinger, Christian
AU - Baust, Maximilian
AU - Tibrewal, Radhika
AU - Ghotbi, Reza
AU - Eckstein, Hans Henning
AU - Navab, Nassir
PY - 2011
Y1 - 2011
N2 - In the current clinical workflow of endovascular abdominal aortic repairs (EVAR) a stent graft is inserted into the aneurysmatic aorta under 2D angiographic imaging. Due to the missing depth information in the X-ray visualization, it is highly difficult in particular for junior physicians to place the stent graft in the preoperatively defined position within the aorta. Therefore, advanced 3D visualization of stent grafts is highly required. In this paper, we present a novel algorithm to automatically match a 3D model of the stent graft to an intraoperative 2D image showing the device. By automatic preprocessing and a global-to-local registration approach, we are able to abandon user interaction and still meet the desired robustness. The complexity of our registration scheme is reduced by a semi-simultaneous optimization strategy incorporating constraints that correspond to the geometric model of the stent graft. Via experiments on synthetic, phantom, and real interventional data, we are able to show that the presented method matches the stent graft model to the 2D image data with good accuracy.
AB - In the current clinical workflow of endovascular abdominal aortic repairs (EVAR) a stent graft is inserted into the aneurysmatic aorta under 2D angiographic imaging. Due to the missing depth information in the X-ray visualization, it is highly difficult in particular for junior physicians to place the stent graft in the preoperatively defined position within the aorta. Therefore, advanced 3D visualization of stent grafts is highly required. In this paper, we present a novel algorithm to automatically match a 3D model of the stent graft to an intraoperative 2D image showing the device. By automatic preprocessing and a global-to-local registration approach, we are able to abandon user interaction and still meet the desired robustness. The complexity of our registration scheme is reduced by a semi-simultaneous optimization strategy incorporating constraints that correspond to the geometric model of the stent graft. Via experiments on synthetic, phantom, and real interventional data, we are able to show that the presented method matches the stent graft model to the 2D image data with good accuracy.
UR - http://www.scopus.com/inward/record.url?scp=82255164705&partnerID=8YFLogxK
U2 - 10.1007/978-3-642-23623-5_23
DO - 10.1007/978-3-642-23623-5_23
M3 - Conference contribution
C2 - 22003615
AN - SCOPUS:82255164705
SN - 9783642236228
T3 - Lecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
SP - 178
EP - 185
BT - Medical Image Computing and Computer-Assisted Intervention, MICCAI 2011 - 14th International Conference, Proceedings
PB - Springer Verlag
T2 - 14th International Conference on Medical Image Computing and Computer Assisted Intervention, MICCAI 2011
Y2 - 18 September 2011 through 22 September 2011
ER -