Transfemoral access for valve in valve implantation of an Edwards Sapien XT valve in a stenotic tricuspid bioprosthesis under fluoroscopic guidance

Martin Greif, Rene Schramm, Gerhard Steinbeck, Christian Hagl, Christoph Schmitz, Christian Kupatt

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

5 Zitate (Scopus)

Abstract

A 53-year-old man presented with a high grade stenotic tricuspid bioprosthesis and an inoperable state because of progressive lung disease. Valve replacement was performed transfemorally under local anaesthesia without rapid pacing. Valve positioning was facilitated by the radiopaque frame of the degenerated bioprosthesis. Echocardiography revealed a decrease of peak tricuspid valve gradient from 18to 8 mm Hg. Valve-in-valve implantation of an Edwards Sapien XT valve in a failing tricuspid bioprosthesis is feasible via transfemoral access without general anaesthesia or rapid pacing.

OriginalspracheEnglisch
Seiten (von - bis)1014.e3-1014.e4
FachzeitschriftCanadian Journal of Cardiology
Jahrgang29
Ausgabenummer8
DOIs
PublikationsstatusVeröffentlicht - Aug. 2013
Extern publiziertJa