Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Tracking accuracy evaluation of electromagnetic sensor-based colonoscope tracking method

  • Masahiro Oda
  • , Hiroaki Kondo
  • , Takayuki Kitasaka
  • , Kazuhiro Furukawa
  • , Ryoji Miyahara
  • , Yoshiki Hirooka
  • , Hidemi Goto
  • , Nassir Navab
  • , Kensaku Mori
  • Nagoya University
  • Aichi Institute of Technology
  • Nagoya University Graduate School of Medicine
  • Nagoya University Hospital

Publikation: Beitrag in Buch/Bericht/KonferenzbandKonferenzbeitragBegutachtung

1 Zitat (Scopus)

Abstract

This paper reports a detailed evaluation results of a colonoscope tracking method. A colonoscope tracking method utilizing electromagnetic sensors and a CT volume has been proposed. Tracking accuracy of this method was evaluated by using a colon phantom. In the previously proposed paper, tracking errors were measured only at six points on the colon phantom for the accuracy evaluation. The point number is not enough to evaluate relationships between the tracking errors and positions in the colon. In this paper, we evaluated the colonoscope tracking method based on more detailed measurement results of the tracking errors. We measured tracking errors at 52 points on the colon phantom and visualized magnitudes of the tracking errors. From our experiments, tracking errors in the ascending and descending colons were enough small to perform colonoscope navigations. However, tracking errors in the transverse and descending colons were large due to colon deformations.

OriginalspracheEnglisch
TitelComputer-Assisted and Robotic Endoscopy - 2nd International Workshop, CARE 2015, Held in Conjunction with MICCAI 2015, Revised Selected Papers
Redakteure/-innenTobias Reichl, Austin Reiter, Xiongbiao Luo, Gian-Luca Mariottini, Xiongbiao Luo
Herausgeber (Verlag)Springer Verlag
Seiten101-108
Seitenumfang8
ISBN (Print)9783319299648
DOIs
PublikationsstatusVeröffentlicht - 2016
Veranstaltung2nd International Workshop on Computer-Assisted and Robotic Endoscopy, CARE 2015 - Munich, Deutschland
Dauer: 5 Okt. 20155 Okt. 2015

Publikationsreihe

NameLecture Notes in Computer Science (including subseries Lecture Notes in Artificial Intelligence and Lecture Notes in Bioinformatics)
Band9515
ISSN (Print)0302-9743
ISSN (elektronisch)1611-3349

Konferenz

Konferenz2nd International Workshop on Computer-Assisted and Robotic Endoscopy, CARE 2015
Land/GebietDeutschland
OrtMunich
Zeitraum5/10/155/10/15

Fingerprint

Untersuchen Sie die Forschungsthemen von „Tracking accuracy evaluation of electromagnetic sensor-based colonoscope tracking method“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren