TY - JOUR
T1 - Trace organic chemical attenuation during managed aquifer recharge
T2 - Insights from a variably saturated 2D tank experiment
AU - Regnery, Julia
AU - Lee, Jonghyun
AU - Drumheller, Zachary W.
AU - Drewes, Jörg E.
AU - Illangasekare, Tissa H.
AU - Kitanidis, Peter K.
AU - McCray, John E.
AU - Smits, Kathleen M.
N1 - Publisher Copyright:
© 2017 Elsevier B.V.
PY - 2017/5/1
Y1 - 2017/5/1
N2 - Meaningful model-based predictions of water quality and quantity are imperative for the designed footprint of managed aquifer recharge installations. A two-dimensional (2D) synthetic MAR system equipped with automated sensors (temperature, water pressure, conductivity, soil moisture, oxidation-reduction potential) and embedded water sampling ports was used to test and model fundamental subsurface processes during surface spreading managed aquifer recharge operations under controlled flow and redox conditions at the meso-scale. The fate and transport of contaminants in the variably saturated synthetic aquifer were simulated using the finite element analysis model, FEFLOW. In general, the model concurred with travel times derived from contaminant breakthrough curves at individual sensor locations throughout the 2D tank. However, discrepancies between measured and simulated trace organic chemical concentrations (i.e., carbamazepine, sulfamethoxazole, tris (2-chloroethyl) phosphate, trimethoprim) were observed. While the FEFLOW simulation of breakthrough curves captured overall shapes of trace organic chemical concentrations well, the model struggled with matching individual data points, although compound-specific attenuation parameters were used. Interestingly, despite steady-state operation, oxidation-reduction potential measurements indicated temporal disturbances in hydraulic properties in the saturated zone of the 2D tank that affected water quality.
AB - Meaningful model-based predictions of water quality and quantity are imperative for the designed footprint of managed aquifer recharge installations. A two-dimensional (2D) synthetic MAR system equipped with automated sensors (temperature, water pressure, conductivity, soil moisture, oxidation-reduction potential) and embedded water sampling ports was used to test and model fundamental subsurface processes during surface spreading managed aquifer recharge operations under controlled flow and redox conditions at the meso-scale. The fate and transport of contaminants in the variably saturated synthetic aquifer were simulated using the finite element analysis model, FEFLOW. In general, the model concurred with travel times derived from contaminant breakthrough curves at individual sensor locations throughout the 2D tank. However, discrepancies between measured and simulated trace organic chemical concentrations (i.e., carbamazepine, sulfamethoxazole, tris (2-chloroethyl) phosphate, trimethoprim) were observed. While the FEFLOW simulation of breakthrough curves captured overall shapes of trace organic chemical concentrations well, the model struggled with matching individual data points, although compound-specific attenuation parameters were used. Interestingly, despite steady-state operation, oxidation-reduction potential measurements indicated temporal disturbances in hydraulic properties in the saturated zone of the 2D tank that affected water quality.
KW - Contaminant fate and transport
KW - FEFLOW
KW - Managed aquifer recharge
KW - Oxidation-reduction potential
KW - Sensors
UR - http://www.scopus.com/inward/record.url?scp=85016442124&partnerID=8YFLogxK
U2 - 10.1016/j.jhydrol.2017.03.038
DO - 10.1016/j.jhydrol.2017.03.038
M3 - Article
AN - SCOPUS:85016442124
SN - 0022-1694
VL - 548
SP - 641
EP - 651
JO - Journal of Hydrology
JF - Journal of Hydrology
ER -