Reduction of radiation dose estimates in cardiac 64-slice CT angiography in patients after coronary artery bypass graft surgery

Franziska Hermann, Stefan Martinoff, Tanja Meyer, Martin Hadamitzky, Chaohui Jiang, Eva Hendrich, Jörg Hausleiter

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

48 Zitate (Scopus)

Abstract

OBJECTIVES: The objectives of this prospective investigation in patients after bypass graft surgery were (1) to estimate radiation dose for routine bypass graft computed tomography (CT) angiography, (2) to study the impact of anatomically adapted and ECG-controlled tube current modulation on radiation dose estimates, and (3) effects on qualitative and quantitative image quality parameters. METHODS: Radiation dose was estimated for 194 consecutive patients undergoing 64-slice CT angiography (Somatom Sensation 64 Cardiac, Siemens Medical Solutions). The impact of anatomically adapted tube current modulation was studied in 2 consecutive patients groups. Furthermore, the impact of ECG-controlled tube current modulation, applied as indicated, was evaluated in both groups. RESULTS: Mean radiation dose estimate for a 64-slice CT bypass graft study was 18.9 ± 6.0 mSv (CTDIvol 42.3 ± 12.9 mGy). The application of anatomically adapted tube current modulation had no effect on dose parameters (CTDIvol 43.3 ± 13.2 vs. 40.1 ± 12.1 mGy for those with versus those without anatomically adapted tube current modulation, P = 0.1). Additional implementation of ECG-controlled tube current modulation resulted in reduced dose parameters (CTDIvol of 32.9 ± 2.6 vs. 58.9 ± 3.9 mGy and radiation dose estimates: 14.7 ± 1.9 mSv vs. 26.5 ± 2.1 mSv for those with versus those without ECG pulsing, both P < 0.01). There was no deterioration in image quality with use of tube current modulation algorithms. CONCLUSIONS: The radiation burden associated with 64-slice bypass graft CT angiographies is substantial. Anatomically adapted tube current modulation does not reduce radiation dose parameters, whereas ECG-controlled tube current modulation was associated with a 45% reduction in dose estimates. Application of both tube current modulation algorithms did not result in reduced image quality.

OriginalspracheEnglisch
Seiten (von - bis)253-260
Seitenumfang8
FachzeitschriftInvestigative Radiology
Jahrgang43
Ausgabenummer4
DOIs
PublikationsstatusVeröffentlicht - Apr. 2008

Fingerprint

Untersuchen Sie die Forschungsthemen von „Reduction of radiation dose estimates in cardiac 64-slice CT angiography in patients after coronary artery bypass graft surgery“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren