TY - GEN
T1 - Real-time screening system using living cells for chemosensitivity testing
AU - Becker, Bernhard
AU - Etzbach, Simona
AU - Schmidhuber, Michael
AU - Grundl, Daniel
AU - Ilchmann, Florian
AU - Grothe, Helmut
AU - Wolf, Bernhard
PY - 2009
Y1 - 2009
N2 - There is an increasing demand for cellular screening systems. For this purpose our research group has developed an automated highcontent online measurement system for living cells. The system is comprised of a pipetting robot, sensors for measurement of pH, pO2, electric signals and cell adhesion, a digital microscope and a climate chamber. The robot is used for media supply, while the sensors monitor the metabolic and morphological parameters of the cells. Reflected light and fluorescence imaging during the course of an experiment are possible due to the included microscope. Sensors are integrated in a special 24-well micro plate that is placed at a fixed position within the system. Oxygen and pH values are usually measured every 5 to 15 seconds. Experiments over a long period of time (several days) are possible, making the system suitable for applications like pharmaceutical drug screening, in vitro chemosensitivity assays, toxicological studies and analytical histopathology.
AB - There is an increasing demand for cellular screening systems. For this purpose our research group has developed an automated highcontent online measurement system for living cells. The system is comprised of a pipetting robot, sensors for measurement of pH, pO2, electric signals and cell adhesion, a digital microscope and a climate chamber. The robot is used for media supply, while the sensors monitor the metabolic and morphological parameters of the cells. Reflected light and fluorescence imaging during the course of an experiment are possible due to the included microscope. Sensors are integrated in a special 24-well micro plate that is placed at a fixed position within the system. Oxygen and pH values are usually measured every 5 to 15 seconds. Experiments over a long period of time (several days) are possible, making the system suitable for applications like pharmaceutical drug screening, in vitro chemosensitivity assays, toxicological studies and analytical histopathology.
KW - Chemosensitivity
KW - Drug screening
KW - Real time cell based assays
KW - Toxicology
UR - http://www.scopus.com/inward/record.url?scp=70449640165&partnerID=8YFLogxK
U2 - 10.1109/EURCON.2009.5167609
DO - 10.1109/EURCON.2009.5167609
M3 - Conference contribution
AN - SCOPUS:70449640165
SN - 9781424438617
T3 - IEEE EUROCON 2009, EUROCON 2009
SP - 87
EP - 93
BT - IEEE EUROCON 2009, EUROCON 2009
T2 - IEEE EUROCON 2009, EUROCON 2009
Y2 - 18 May 2009 through 23 May 2009
ER -