Abstract
Propagation-based phase-contrast computed tomography has become a valuable tool for visualization of three-dimensional biological samples, due to its high contrast between materials with similar attenuation properties. However, one of the most-widely used phase-retrieval algorithms imposes a homogeneity assumption onto the sample, which leads to artifacts for numerous applications where this assumption is violated. Prominent examples are biological samples with highly-absorbing implants. Using synchrotron radiation, we demonstrate by the example of a guinea pig inner ear with a cochlear implant electrode, how a recently developed model-based iterative algorithm for propagation-based phase-contrast computed tomography yields distinct benefits for such a task. We find that the model-based approach improves the overall image quality, removes the detrimental influence of the implant and accurately visualizes the cochlea.
Originalsprache | Englisch |
---|---|
Aufsatznummer | #337870 |
Seiten (von - bis) | 5330-5339 |
Seitenumfang | 10 |
Fachzeitschrift | Biomedical Optics Express |
Jahrgang | 9 |
Ausgabenummer | 11 |
DOIs | |
Publikationsstatus | Veröffentlicht - 1 Nov. 2018 |