N2 - Aim: The aim of this study was to assess the safety and efficacy profile of a newer generation biodegradable DES, the Yukon Choice PC Elite with a temperature controlling mechanism, in patients with acute coronary syndrome (ACS). Methods: This prospective multi-center study (PIONEER Registry) was conducted in an Indian ACS population, therefore providing data in real world clinical practice. Patients with ACS underwent DES implantation in de novo native-vessel coronary lesions with the Yukon Choice PC Elite biodegradable polymer DES and were followed up for a year. Results: A total 999 patients were evaluated. The majority of patients were male (79.2%). A total of 6.7% of the patients had a history of prior myocardial infarction (MI) and 2.7% of patients had a history of previous coronary artery bypass graft. The clinical presentations of the patients included: unstable angina pectoris (UA) (46.4%), ST-segment elevation MI (STEMI) (38.1%), and Non-ST-segment elevation MI (NSTEMI) (15.4%). Implantation of the device was successful in 99.9% of cases. The median stent length and stent size were 21.0 mm (Range: 8.0–40.0 mm) and 2.8 mm (Range 2.0–4.0 mm), respectively. Through to one-year clinical follow-up after percutaneous coronary intervention, all-cause death occurred in 4 of 999 patients (Crude Percentage: 0.4%). Cardiac death, MI, TLR, and stent thrombosis were occurred in 1 (0.1%), 8 (0.8%), 12 (1.2%) and 1 (0.1%) patients, respectively. Conclusion: The results of this post marketing surveillance registry suggest favorable safety and efficacy outcomes associated with the Yukon Choice PC Elite biodegradable DES in a real world Indian ACS population.
AB - Aim: The aim of this study was to assess the safety and efficacy profile of a newer generation biodegradable DES, the Yukon Choice PC Elite with a temperature controlling mechanism, in patients with acute coronary syndrome (ACS). Methods: This prospective multi-center study (PIONEER Registry) was conducted in an Indian ACS population, therefore providing data in real world clinical practice. Patients with ACS underwent DES implantation in de novo native-vessel coronary lesions with the Yukon Choice PC Elite biodegradable polymer DES and were followed up for a year. Results: A total 999 patients were evaluated. The majority of patients were male (79.2%). A total of 6.7% of the patients had a history of prior myocardial infarction (MI) and 2.7% of patients had a history of previous coronary artery bypass graft. The clinical presentations of the patients included: unstable angina pectoris (UA) (46.4%), ST-segment elevation MI (STEMI) (38.1%), and Non-ST-segment elevation MI (NSTEMI) (15.4%). Implantation of the device was successful in 99.9% of cases. The median stent length and stent size were 21.0 mm (Range: 8.0–40.0 mm) and 2.8 mm (Range 2.0–4.0 mm), respectively. Through to one-year clinical follow-up after percutaneous coronary intervention, all-cause death occurred in 4 of 999 patients (Crude Percentage: 0.4%). Cardiac death, MI, TLR, and stent thrombosis were occurred in 1 (0.1%), 8 (0.8%), 12 (1.2%) and 1 (0.1%) patients, respectively. Conclusion: The results of this post marketing surveillance registry suggest favorable safety and efficacy outcomes associated with the Yukon Choice PC Elite biodegradable DES in a real world Indian ACS population.
KW - Drug eluting stents
KW - Ischemic heart disease
KW - Stent thrombosis
KW - Success rate
UR - http://www.scopus.com/inward/record.url?scp=85147036570&partnerID=8YFLogxK
U2 - 10.1016/j.ihj.2022.12.005
DO - 10.1016/j.ihj.2022.12.005
M3 - Article
C2 - 36567065
AN - SCOPUS:85147036570
SN - 0019-4832
VL - 75
SP - 25
EP - 30
JO - Indian Heart Journal
JF - Indian Heart Journal
IS - 1
ER -