On line and in situ control of aerosol emission from hazardous waste combustion

A. Zajc, E. Uhlig, H. Hackfort, R. Niessner

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

7 Zitate (Scopus)

Abstract

Continous control of Polycyclic Aromatic Hydrocarbons (PAHs) adsorbed on submicron combustion aerosols is still an unsolved problem. A solution might be the Photoelectric Aerosol Sensor (PAS) which has been tested successfully in laboratory experiments to determine PAHs adsorbed on artificially produced carbon particles. The applicability of this sensor as an on line-and in situ-detector for the measurement of PAHs in combustion exhaust gases and the used aerosol characterization techniques are discussed. First results are presented.

OriginalspracheEnglisch
Seiten (von - bis)1465-1468
Seitenumfang4
FachzeitschriftJournal of Aerosol Science
Jahrgang20
Ausgabenummer8
DOIs
PublikationsstatusVeröffentlicht - 1989