TY - JOUR
T1 - Non-invasive measurements of blood glucose levels by time-gating mid-infrared optoacoustic signals
AU - Uluç, Nasire
AU - Glasl, Sarah
AU - Gasparin, Francesca
AU - Yuan, Tao
AU - He, Hailong
AU - Jüstel, Dominik
AU - Pleitez, Miguel A.
AU - Ntziachristos, Vasilis
N1 - Publisher Copyright:
© The Author(s) 2024.
PY - 2024/4
Y1 - 2024/4
N2 - Non-invasive glucose monitoring (NIGM) represents an attractive alternative to finger pricking for blood glucose assessment and management of diabetes. Nevertheless, current NIGM techniques do not measure glucose concentrations in blood but rely on indirect bulk measurement of glucose in interstitial fluid, where glucose is diluted and glucose dynamics are different from those in the blood, which impairs NIGM accuracy. Here we introduce a new biosensor, termed depth-gated mid-infrared optoacoustic sensor (DIROS), which allows, for the first time, non-invasive glucose detection in blood-rich volumes in the skin. DIROS minimizes interference caused by the stratum corneum and other superficial skin layers by time-gating mid-infrared optoacoustic signals to enable depth-selective localization of glucose readings in skin. In measurements on the ears of (female) mice, DIROS displays improved accuracy over bulk-tissue glucose measurements. Our work demonstrates how signal localization can improve NIGM accuracy and positions DIROS as a holistic approach, with high translational potential, that addresses a key limitation of current NIGM methods.
AB - Non-invasive glucose monitoring (NIGM) represents an attractive alternative to finger pricking for blood glucose assessment and management of diabetes. Nevertheless, current NIGM techniques do not measure glucose concentrations in blood but rely on indirect bulk measurement of glucose in interstitial fluid, where glucose is diluted and glucose dynamics are different from those in the blood, which impairs NIGM accuracy. Here we introduce a new biosensor, termed depth-gated mid-infrared optoacoustic sensor (DIROS), which allows, for the first time, non-invasive glucose detection in blood-rich volumes in the skin. DIROS minimizes interference caused by the stratum corneum and other superficial skin layers by time-gating mid-infrared optoacoustic signals to enable depth-selective localization of glucose readings in skin. In measurements on the ears of (female) mice, DIROS displays improved accuracy over bulk-tissue glucose measurements. Our work demonstrates how signal localization can improve NIGM accuracy and positions DIROS as a holistic approach, with high translational potential, that addresses a key limitation of current NIGM methods.
UR - http://www.scopus.com/inward/record.url?scp=85189009177&partnerID=8YFLogxK
U2 - 10.1038/s42255-024-01016-9
DO - 10.1038/s42255-024-01016-9
M3 - Letter
C2 - 38538980
AN - SCOPUS:85189009177
SN - 2522-5812
VL - 6
SP - 678
EP - 686
JO - Nature Metabolism
JF - Nature Metabolism
IS - 4
ER -