Instrumentation for Nuclear Fusion

Publikation: Beitrag in Buch/Bericht/KonferenzbandKapitelBegutachtung

Abstract

To characterize a fusion plasma in an adequate way and to understand its complex behavior as completely as possible, a large number of different plasma parameters must be determined simultaneously. Most of them are local quantities varying with the radial coordinate and in time. The spatial resolution aimed at is 1-5cm, and the required time resolution varies from µs to ms depending on the measured quantity. The demanded accuracy of all the measuring systems is typically 1-10%. The major challenge for fusion plasma diagnostic originates from the harsh environment they are exposed to. When proceeding to future burning-plasma devices, these burdens will further increase mainly due to the strongly increased neutron fluence and energy load during the lifetime of the diagnostic. This chapter sketches basic nuclear fusion and concentrates on diagnostic areas where radiation detectors are involved, factoring out completely the wide field of electromagnetic measurements and laser-aided methods.

OriginalspracheEnglisch
TitelHandbook of Particle Detection and Imaging
UntertitelSecond Edition
Herausgeber (Verlag)Springer International Publishing
Seiten1075-1095
Seitenumfang21
ISBN (elektronisch)9783319937854
ISBN (Print)9783319937847
DOIs
PublikationsstatusVeröffentlicht - 1 Jan. 2021
Extern publiziertJa

Fingerprint

Untersuchen Sie die Forschungsthemen von „Instrumentation for Nuclear Fusion“. Zusammen bilden sie einen einzigartigen Fingerprint.