Improving surgical results in complex nerve anatomy during implantation of selective upper airway stimulation

Zhaojun Zhu, Benedikt Hofauer, Clemens Heiser

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

7 Zitate (Scopus)

Abstract

The following report presents a case of two late embedded hypoglossus branches during implantation of an upper airway stimulation device that caused a mixed activation of the tongue when included in the stimulation cuff. In the end, correct cuff placement could be achieved by careful examination of the hypoglossal nerve anatomy, precise nerve dissection, tongue motion analysis and intraoperative nerve monitoring.

OriginalspracheEnglisch
Seiten (von - bis)653-656
Seitenumfang4
FachzeitschriftAuris Nasus Larynx
Jahrgang45
Ausgabenummer3
DOIs
PublikationsstatusVeröffentlicht - Juni 2018