Implementation of a sagittal T2-weighted DIXON turbo spin-echo sequence may shorten MRI acquisitions in the emergency setting of suspected spinal bleeding

Nico Sollmann, Charlotte Rüther, Simon Schön, Claus Zimmer, Thomas Baum, Jan S. Kirschke

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

3 Zitate (Scopus)

Abstract

Background: Magnetic resonance imaging (MRI) is the modality of choice for evaluating soft tissue damage along the spine in the emergency setting, yet access and fast protocol availability are limited. We assessed the performance of a sagittal T2-weighted DIXON turbo spin-echo sequence and investigated whether additional standard sagittal T1-weighted sequences are necessary in suspected spinal fluid collections/bleedings. Methods: Seventy-four patients aged 62.9 ± 19.3 years (mean ± standard deviation) with MRI including a sagittal T2-weighted DIXON sequence and a T1-weighted sequence were retrospectively included. Thirty-four patients (45.9%) showed a spinal fluid collection/bleeding. Two layouts (layout 1: fat-only and water-only and in-phase images of the DIXON sequence and T1-weighted images; layout 2: fat-only and water-only and in-phase images of the DIXON sequence) were evaluated by three readers (R1, R2, and R3) concerning presence of spinal fluid collections/bleedings and diagnostic confidence from 1 (very low confidence) to 5 (very high confidence). χ2 and κ statistics were used. Results: There was no difference in detecting spinal fluid collections/bleedings between the layouts (R1 and R2 detected all, R3 missed one spinal fluid collection/bleeding in the same patient in both layouts). Confidence was high (layout 1, R1 4.26 ± 0.81, R2 4.28 ± 0.81, R3 4.32 ± 0.79; layout 2, R1 3.93 ± 0.70, R2 4.09 ± 0.86, R3 3.97 ± 0.73), with higher inter-reader agreement for layout 1 (κ 0.691–0.780) than for layout 2 (κ 0.441–0.674). Conclusions: A sagittal T2-weighted DIXON sequence provides diagnostic performance similar to a protocol including standard T1-weighted sequences.

OriginalspracheEnglisch
Aufsatznummer19
FachzeitschriftEuropean Radiology Experimental
Jahrgang5
Ausgabenummer1
DOIs
PublikationsstatusVeröffentlicht - Dez. 2021
Extern publiziertJa

Fingerprint

Untersuchen Sie die Forschungsthemen von „Implementation of a sagittal T2-weighted DIXON turbo spin-echo sequence may shorten MRI acquisitions in the emergency setting of suspected spinal bleeding“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren