Abstract
Imrnunoaffinity chromatography (IAC) provides a selective method for sample preparation prior to high-performance liquid chromatography (HPLC) or gas chromatography (GC). Five different support materials were tested for their suitability with regard to IAC of herbicides (s-triazines). Three gels showing low (0–10 %) nonspecific s-triazine adsorption were used as affinity supports (Beaded cellulose ONB-carbonate A, LiChroprep hydrazide tentacle gel and LiChroprep azlactone gel). A monoclonal antibody (K4E7), directed against atrazine, was covalently coupled to the gels. High antibody immobilization rates (100 %) were obtained with the beaded cellulose gel in comparison to the other gels (60–70 %). Subsequently the IAC columns were loaded with triazine solutions. Glycine-HCl 0.2 mol/L, pH 2.2 yielded the best results for the elution of the bound triazines from the beaded cellulose IAC columns (70–100 %). Both the hydrazide tentacle and the azlactone IAC columns showed lower elution rates (60–80 %).
Originalsprache | Englisch |
---|---|
Seiten (von - bis) | 267-278 |
Seitenumfang | 12 |
Fachzeitschrift | Analytical Letters |
Jahrgang | 28 |
Ausgabenummer | 2 |
DOIs | |
Publikationsstatus | Veröffentlicht - 1 Jan. 1995 |