Acknowledgments This work was supported by the Deutsche Forschungsgemeinschaft under grants NA 620/2-1 and 446 JAP 113/348/0-1, the European Union FP7 under grant 256984, the JSPS Grant for Scientific Research, and the TUM Graduate School of Information Science in Health (GSISH). The authors would like to thank Marco Feuerstein for help with Fig. 6.
PY - 2013/11
Y1 - 2013/11
N2 - Purpose: Flexible fiber-optic bronchoscopy is a widespread medical procedure for the diagnosis and treatment of lung diseases. Navigation systems are needed to track the flexible endoscope within the bronchial tree. Electromagnetic (EM) tracking is currently the only technology used clinically for this purpose. The registration between EM tracking and patient anatomy may become inaccurate due to breathing motion, so the addition of image-based tracking has been proposed as a hybrid EM-image-based system. Methods: When EM tracking is used as an initialization for image registration, small changes in the initialization may lead to different local minima and noise is amplified by hybrid tracking. The tracking output is modeled as continuous and uses splines for interpolation, thus smoothness is greatly improved. The bronchoscope pose relative to computed tomography data is interpolated using Catmull-Rom splines for position and spherical linear interpolation (SLERP) for orientation. Results: The hybrid method was evaluated using ground truth poses manually selected by experts, where mean inter-expert agreement was determined as 1.26 mm. Using four dynamic phantom data sets, the accuracy was 4.91 mm, which is equivalent to previous methods. Compared to state-of-art methods, inter-frame smoothness was improved from 2.77-3.72 to 1.24 mm. Conclusions: Hybrid image and electromagnetic endoscope guidance provides a more realistic and physically plausible solution with significantly less jitter. This quantitative result is confirmed by visual comparison of real and virtual video, where the virtual video output is much more consistent and robust, with fewer occasions of tracking loss or unexpected movement compared with previous methods.
AB - Purpose: Flexible fiber-optic bronchoscopy is a widespread medical procedure for the diagnosis and treatment of lung diseases. Navigation systems are needed to track the flexible endoscope within the bronchial tree. Electromagnetic (EM) tracking is currently the only technology used clinically for this purpose. The registration between EM tracking and patient anatomy may become inaccurate due to breathing motion, so the addition of image-based tracking has been proposed as a hybrid EM-image-based system. Methods: When EM tracking is used as an initialization for image registration, small changes in the initialization may lead to different local minima and noise is amplified by hybrid tracking. The tracking output is modeled as continuous and uses splines for interpolation, thus smoothness is greatly improved. The bronchoscope pose relative to computed tomography data is interpolated using Catmull-Rom splines for position and spherical linear interpolation (SLERP) for orientation. Results: The hybrid method was evaluated using ground truth poses manually selected by experts, where mean inter-expert agreement was determined as 1.26 mm. Using four dynamic phantom data sets, the accuracy was 4.91 mm, which is equivalent to previous methods. Compared to state-of-art methods, inter-frame smoothness was improved from 2.77-3.72 to 1.24 mm. Conclusions: Hybrid image and electromagnetic endoscope guidance provides a more realistic and physically plausible solution with significantly less jitter. This quantitative result is confirmed by visual comparison of real and virtual video, where the virtual video output is much more consistent and robust, with fewer occasions of tracking loss or unexpected movement compared with previous methods.
KW - 2D/3D image registration
KW - Electromagnetic tracking
KW - Endoscopic procedures
KW - Intraoperative imaging
KW - Localization and tracking technologies
UR - http://www.scopus.com/inward/record.url?scp=84888303823&partnerID=8YFLogxK
U2 - 10.1007/s11548-013-0835-5
DO - 10.1007/s11548-013-0835-5
M3 - Article
C2 - 23543323
AN - SCOPUS:84888303823
SN - 1861-6410
VL - 8
SP - 955
EP - 965
JO - International Journal of Computer Assisted Radiology and Surgery
JF - International Journal of Computer Assisted Radiology and Surgery
IS - 6
ER -