Zur Hauptnavigation wechseln Zur Suche wechseln Zum Hauptinhalt wechseln

Evaluation of a marker-less, intra-operative, augmented reality guidance system for robot-assisted laparoscopic radical prostatectomy

  • Megha Kalia
  • , Prateek Mathur
  • , Keith Tsang
  • , Peter Black
  • , Nassir Navab
  • , Septimiu Salcudean
  • University of British Columbia
  • Technische Universität München

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

14 Zitate (Scopus)

Abstract

Purpose: Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical robot is a common treatment for organ-confined prostate cancer. Augmented reality (AR) can help during RALRP by showing the surgeon the location of anatomical structures and tumors from preoperative imaging. Previously, we proposed hand-eye and camera intrinsic matrix estimation procedures that can be carried out with conventional instruments within the patient during surgery, take < 3 min to perform, and fit seamlessly in the existing surgical workflow. In this paper, we describe and evaluate a complete AR guidance system for RALRP and quantify its accuracy. Methods: Our AR system requires three transformations: the transrectal ultrasound (TRUS) to da Vinci transformation, the camera intrinsic matrix, and the hand-eye transformation. For evaluation, a 3D-printed cross-wire was visualized in TRUS and stereo endoscope in a water bath. Manually triangulated cross-wire points from stereo images were used as ground truth to evaluate overall TRE between these points and points transformed from TRUS to camera. Results: After transforming the ground-truth points from the TRUS to the camera coordinate frame, the mean target registration error (TRE) (SD) was 4.56 ± 1.57 mm. The mean TREs (SD) in the x-, y-, and z-directions are 1.93 ± 1.26 mm, 2.04 ± 1.37 mm, and 2.94 ± 1.84 mm, respectively. Conclusions: We describe and evaluate a complete AR guidance system for RALRP which can augment preoperative data to endoscope camera image, after a deformable magnetic resonance image to TRUS registration step. The streamlined procedures with current surgical workflow and low TRE demonstrate the compatibility and readiness of the system for clinical translation. A detailed sensitivity study remains part of future work.

OriginalspracheEnglisch
Seiten (von - bis)1225-1233
Seitenumfang9
FachzeitschriftInternational Journal of Computer Assisted Radiology and Surgery
Jahrgang15
Ausgabenummer7
DOIs
PublikationsstatusVeröffentlicht - 1 Juli 2020

UN SDGs

Dieser Output leistet einen Beitrag zu folgendem(n) Ziel(en) für nachhaltige Entwicklung

  1. SDG 3 – Gute Gesundheit und Wohlergehen
    SDG 3 – Gute Gesundheit und Wohlergehen

Fingerprint

Untersuchen Sie die Forschungsthemen von „Evaluation of a marker-less, intra-operative, augmented reality guidance system for robot-assisted laparoscopic radical prostatectomy“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren