Establishment of triglyceride cut-off values to detect chylous ascites and pleural effusions

  • Markus A. Thaler
  • , Andreas Bietenbeck
  • , Christoph Schulz
  • , Peter B. Luppa
  • Technische Universität München

Publikation: Beitrag in FachzeitschriftArtikelBegutachtung

32 Zitate (Scopus)

Abstract

Objectives Lipoprotein electrophoresis is the gold standard for the detection of chylous ascites and pleural effusions. It is, however, not suitable as a front-line test and not widely available. Most clinicians must rely solely on the quantitative determination of lipids. The aim of this work was to establish lipid cut-off values for the presence of chylomicrons in pleural and peritoneal fluid. Design and methods Triglyceride and cholesterol levels from 113 peritoneal and 154 pleural fluid samples investigated for chylomicrons via lipoprotein electrophoresis were considered. Receiver operating characteristic analyses were performed and cut-off levels determined. Results 54 peritoneal and 59 pleural fluid samples were positive for chylomicrons. In peritoneal fluid, triglycerides and triglycerides/cholesterol ratio exhibited areas under the curve (AUC) not significantly different from each other, but significantly larger than cholesterol alone. The AUC for triglycerides in pleural fluid was significantly larger than the AUCs for cholesterol and the triglycerides/cholesterol ratio. Triglyceride cut-offs with maximum Youden-Index, sensitivity > 95%, and specificity > 95% were calculated to be 187, 148, and 246 mg/dl (2.13, 1.69, and 2.80 mmol/l) for peritoneal fluid, and 240, 94, and 240 mg/dl (2.74, 1.07, and 2.74 mmol/l) for pleural fluid. Conclusions Triglyceride levels are the best parameter to detect chylous body fluids when lipoprotein electrophoresis is not available. Single-point triglyceride cut-offs of 187 and 240 mg/dl (2.13 and 2.74 mmol/l) or alternatively equivocal ranges of 148–246 and 94–240 mg/dl (1.69–2.80 and 1.07–2.74 mmol/l) were established for peritoneal and pleural fluid, respectively.

OriginalspracheEnglisch
Seiten (von - bis)134-138
Seitenumfang5
FachzeitschriftClinical Biochemistry
Jahrgang50
Ausgabenummer3
DOIs
PublikationsstatusVeröffentlicht - 1 Feb. 2017

Fingerprint

Untersuchen Sie die Forschungsthemen von „Establishment of triglyceride cut-off values to detect chylous ascites and pleural effusions“. Zusammen bilden sie einen einzigartigen Fingerprint.

Dieses zitieren