TY - JOUR
T1 - Efficiency and economic analysis of utilizing latent heat from groundwater freezing in the context of borehole heat exchanger coupled ground source heat pump systems
AU - Zheng, Tianyuan
AU - Shao, Haibing
AU - Schelenz, Sophie
AU - Hein, Philipp
AU - Vienken, Thomas
AU - Pang, Zhonghe
AU - Kolditz, Olaf
AU - Nagel, Thomas
N1 - Publisher Copyright:
© 2016 Elsevier Ltd. All rights reserved.
PY - 2016/7/25
Y1 - 2016/7/25
N2 - To utilize the shallow geothermal energy, heat pumps are often coupled with borehole heat exchangers (BHE) to provide heating and cooling for buildings. In cold regions, soil freezing around the BHE is a potential problem which will dramatically influence the underground soil temperature distribution, subsequently the inlet and outlet circulating fluid temperature of the BHE, and finally the efficiency of the heat pump. In this study, a numerical model has been developed to simulate the coupled temperature evolution both inside the BHE, and the propagating freezing front in the surrounding soil. The coupled model was validated against analytical solutions and experimental data. The influence of the freezing process on the overall system performance is investigated by comparing one long BHE configuration without freezing and another short one with latent heat from the frozen groundwater. It is found that when freezing happens, the coefficient of performance (COP) of the heat pump will decrease by around 0.5, leading to more electricity consumption. Furthermore, analysis of the simulation result reveals that the exploitation of latent heat through groundwater freezing is only economically attractive if electricity price is low and interest rate high, and it is not the case is most European countries.
AB - To utilize the shallow geothermal energy, heat pumps are often coupled with borehole heat exchangers (BHE) to provide heating and cooling for buildings. In cold regions, soil freezing around the BHE is a potential problem which will dramatically influence the underground soil temperature distribution, subsequently the inlet and outlet circulating fluid temperature of the BHE, and finally the efficiency of the heat pump. In this study, a numerical model has been developed to simulate the coupled temperature evolution both inside the BHE, and the propagating freezing front in the surrounding soil. The coupled model was validated against analytical solutions and experimental data. The influence of the freezing process on the overall system performance is investigated by comparing one long BHE configuration without freezing and another short one with latent heat from the frozen groundwater. It is found that when freezing happens, the coefficient of performance (COP) of the heat pump will decrease by around 0.5, leading to more electricity consumption. Furthermore, analysis of the simulation result reveals that the exploitation of latent heat through groundwater freezing is only economically attractive if electricity price is low and interest rate high, and it is not the case is most European countries.
KW - Borehole heat exchanger (BHE)
KW - Coefficient of performance (COP)
KW - Ground source heat pump system (GSHPS)
KW - OpenGeoSys
KW - Shallow geothermal energy
KW - Soil freezing
UR - http://www.scopus.com/inward/record.url?scp=84973163558&partnerID=8YFLogxK
U2 - 10.1016/j.applthermaleng.2016.05.158
DO - 10.1016/j.applthermaleng.2016.05.158
M3 - Article
AN - SCOPUS:84973163558
SN - 1359-4311
VL - 105
SP - 314
EP - 326
JO - Applied Thermal Engineering
JF - Applied Thermal Engineering
ER -